AI Article Synopsis

Article Abstract

We demonstrate electrically pumped two-section mode locked quantum well lasers emitting at the L-band of telecommunication wavelength on silicon utilizing die to wafer bonding techniques. The mode locked lasers generate pulses at a repetition frequency of 30 GHz with signal to noise ratio above 30 dB and 1 mW average output power per facet. Optical injection-locking scheme was used to improve the noise properties of the pulse trains of passively mode-locked laser. The phases of the mode-locked frequency comb are shown to be coherent with that of the master continuous-wave (CW) laser. The radio-frequency (RF)-line-width is reduced from 7.6 MHz to 150 kHz under CW optical injection. The corresponding pulse-to-pulse jitter and integrated RMS jitter are 29.7 fs/cycle and 1.0 ps, respectively. The experimental results demonstrate that optical injection can reduce the noise properties of the passively mode locked III-V/Si laser in terms of frequency linewidth and timing jitter, which makes the devices attractive for photonic analog-to-digital converters and clock generation and recovery.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.23.006392DOI Listing

Publication Analysis

Top Keywords

optical injection
12
mode locked
12
passively mode-locked
8
noise properties
8
mode-locked iii-v/silicon
4
laser
4
iii-v/silicon laser
4
laser continuous-wave
4
optical
4
continuous-wave optical
4

Similar Publications

Purpose: This study aimed to evaluate early-phase safety of subretinal application of AAVanc80.CAG.USH1Ca1 (OT_USH_101) in wild-type (WT) pigs, examining the effects of a vehicle control, low dose, and high dose.

View Article and Find Full Text PDF

Povidone-iodine (PI) is the standard antiseptic for intravitreal injections (IVIs), while chlorhexidine (CHX) is a potential alternative. The efficacy of PI versus CHX in preventing endophthalmitis remains debated, with studies showing mixed results. To compare the effectiveness of using PI compared with CHX in IVI procedures regarding endophthalmitis rates, culture-positive endophthalmitis rates, and changes in visual acuity.

View Article and Find Full Text PDF

Topographic Analysis of the Periorbital Region Including Orbicularis Oculi Muscle Based on Ultrasonography Interpretation.

J Cosmet Dermatol

January 2025

Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry, Seoul, South Korea.

Objective: Ultrasonographic examination is easy, fast, safe, and used in various fields; however, its application to the facial area has been limited. Complex anatomical structures are mixed within thin, soft tissues in the facial region; therefore, understanding their structural characteristics is crucial. This study aimed to use ultrasonography to obtain information on the layered structure and soft tissue thickness of the eye area around the orbicularis oculi muscle and provide guidance for clinical practice.

View Article and Find Full Text PDF

Edge contacts offer a significant advantage for enhancing the performance of semiconducting transition metal dichalcogenide (TMDC) devices by interfacing with the metallic contacts on the lateral side, which allows the encapsulation of all of the channel material. However, despite intense research, the fabrication of feasible electrical edge contacts to TMDCs to improve device performance remains a great challenge, as interfacial chemical characterization via conventional methods is lacking. A major bottleneck in explicitly understanding the chemical and electronic properties of the edge contact at the metal-two-dimensional (2D) semiconductor interface is the small cross section when characterizing nominally one-dimensional edge contacts.

View Article and Find Full Text PDF

The unique optical properties of perovskite quantum dots (PQDs), particularly the tunable photoluminescence (PL) across the visible spectrum, make them a promising tool for chlorinated detection. However, the correlation between the fluorescence emission shift behavior and the interface of phase transformation in PQDs has not been thoroughly explored. In this study, we synthesized CsPbBr PQDs via the hot-injection method and demonstrated their ability to detect chlorinated volatile compounds such as HCl and NaOCl through a halide exchange process between the PQDs' solid thin film and the chlorinated vapor phase.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!