Ocular Biometrics of Myopic Eyes With Narrow Angles.

J Glaucoma

*Department of Ophthalmology, Duke University Eye Center, Durham, NC †Singapore National Eye Centre, Singapore, Singapore.

Published: February 2016

Purpose: The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles.

Methods: Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster.

Results: A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15).

Conclusions: Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0000000000000130DOI Listing

Publication Analysis

Top Keywords

narrow angles
24
eyes narrow
12
patients eyes
12
ocular biometrics
8
biometrics myopic
8
myopic eyes
8
angles
8
patients narrow
8
eyes classified
8
open angles
8

Similar Publications

Förster resonance energy transfer (FRET) is becoming a valuable technique in gas-phase structural biology for identifying local structural motifs and conformations of biological molecules, such as peptides and proteins. This method involves labeling the biomolecule with two dyes, a donor dye and an acceptor dye, that are commonly charged rhodamines. Here we examine how different amino acid (AA) methyl esters linked to the dye via amide linkages can influence the dye transition energy and, consequently, the energy-transfer efficiency, using cryogenic ion fluorescence spectroscopy.

View Article and Find Full Text PDF

In recent years, research on chiral bound states in the continuum (BIC) has surged, leading to the development of various chiral metasurfaces with narrow bandwidths by breaking of in-plane and out-of-plane symmetries. However, the ability to dynamically tune the working band remains relatively unexplored, which is valuable for chiral sensing applications. Optical phase-change materials, with tunable dielectric constants and switchable properties during phase transition, offer the potential for dynamic control of optical metasurfaces.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of a surgical procedure (extended strip craniectomy with bilateral barrel staving) for treating isolated craniosynostosis of the sagittal suture in infants, specifically focusing on its impact on cranial shape without directly addressing forehead issues.
  • Results showed significant improvements in aspects like bossing angle and cephalic index over a year, although the cranial shape did not entirely match that of healthy peers, indicating partial normalization but not complete correction.
  • The research validates 3D photogrammetry as a useful noninvasive tool for assessing cranial changes post-surgery, suggesting potential for wider clinical applications in monitoring cranial morphology.
View Article and Find Full Text PDF

Objective: Sagittal synostosis is the most common type of craniosynostosis, resulting in deformity with distinctive morphological characteristics. These include occipital narrowing, parietal narrowing, anteriorly shifted vertex with parietal depression, and exaggerated frontal bossing. The traditional cephalic index affords limited reliability in quantifying initial severity and correction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!