A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of archwire cross-section changes on force levels during complex tooth alignment with conventional and self-ligating brackets. | LitMetric

Effect of archwire cross-section changes on force levels during complex tooth alignment with conventional and self-ligating brackets.

Am J Orthod Dentofacial Orthop

Cendres+Métaux Endowed professor, Department of Oral Technology, School of Dentistry, University of Bonn, Bonn, Germany.

Published: April 2015

Introduction: Our objective was to investigate the effect of archwire cross-section increases on the levels of force applied to teeth during complex malalignment correction with various archwire-bracket combinations using an experimental biomechanical setup.

Methods: The study comprised 3 types of orthodontic brackets: (1) conventional ligating brackets (Victory Series [3M Unitek, Monrovia, Calif] and Mini-Taurus [Rocky Mountain Orthodontics, Denver, Colo]), (2) self-ligating brackets (SmartClip, a passive self-ligating bracket [3M Unitek]; and Time3 [Rocky Mountain Orthodontics, Denver, Colo] and SPEED [Strite Industries, Cambridge, Ontario, Canada], both active self-ligating brackets), and (3) a conventional low-friction bracket (Synergy [Rocky Mountain Orthodontics]). All brackets had a nominal 0.022-in slot size. The brackets were combined with 0.014-in and 0.016-in titanium memory wires, Therma-Ti archwires (American Orthodontics, Sheboygan, Wis). The archwires were tied to the conventional brackets with both stainless steel ligatures of size 0.010-in and elastomeric rings. A malocclusion of the maxillary central incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis) was simulated.

Results: The forces recorded when using the 0.014-in archwires ranged from 1.7 ± 0.1 to 5.0 ± 0.3 N in the x-axis direction, and from 1.2 ± 0.1 to 5.5 ± 0.3 N in the z-axis direction. When we used the 0.016-in archwires, the forces ranged from 2.6 ± 0.1 to 6.0 ± 0.3 N in the x-axis direction, and from 2.0 ± 0.2 to 6.0 ± 0.4 N in the z-axis direction. Overall, the increases ranged from 16.0% to 120.0% in the x-axis and from 10.4% to 130.0% in the z-axis directions.

Conclusions: Increasing the cross section of the wire increased the force level invariably with all brackets. Wires of size 0.014 in produced relatively high force levels, and the force level increased with 0.016-in wires.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajodo.2014.11.024DOI Listing

Publication Analysis

Top Keywords

self-ligating brackets
12
[rocky mountain
12
brackets
9
archwire cross-section
8
force levels
8
levels force
8
brackets conventional
8
mountain orthodontics
8
orthodontics denver
8
denver colo]
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!