A novel design of Rogowski coil for measurement of nanosecond-risetime high-level pulsed current.

Rev Sci Instrum

State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China.

Published: March 2015

In pulsed power systems, pulsed currents with risetimes from nanosecond to microsecond can be effectively measured by self-integrating Rogowski coils. Appropriate design of the structure and the integrating resistor is crucial to the high-frequency response of a coil. In this paper, several novel designs of Rogowski coil's integrating resistors were proposed and tested. Experimental results showed that the optimized coil could response square waves with fronts of ∼1.5 ns and had a sensitivity of ∼0.75 V/kA. The maximal peak current was designed as 100 kA.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4916094DOI Listing