Aim And Background: In clinical practice, we come across patients with traumatically amputated or congenitally missing partial or complete fingers that can be restored using microsurgical replantation or transplantation procedures. However, in some cases this might not be possible due to systemic or local factors and the lost or missing part has to be replaced prosthetically to offer psychological and functional wellbeing. These prostheses can be constructed with various materials like acrylics or silicone retained with the help of auxiliary aids. However, these prostheses cause some hindrance in performing functions like writing, typing, etc. The aim of the present trial was to ameliorate the existing design of implant supported finger prosthesis.
Technique: Distal phalange of middle finger replaced with implant supported silicone finger prosthesis is modified by utilizing a metal framework to support silicone material to improve rigidity while working.
Conclusion And Clinical Significance: We could achieve a good function, esthetics and tactile sensibility with this modified design. Whenever, feasible this design can improve the performance and patients feel a deep sense of satisfaction and improved self-esteem with this modified prosthesis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5005/jp-journals-10024-1624 | DOI Listing |
Sci Rep
January 2025
Mechanical and Industrial Engineering Department, Universitas Gadjah Mada, Yogyakarta, Indonesia.
Research on flexible strain sensors has grown rapidly and is widely applied in the fields of soft robotics, body motion detection, wearable sensors, health monitoring, and sports. In this study, MXene was successfully synthesized in powder form and combined with multi-walled carbon nanotube (MWCNT) to develop MWCNT@MXene conductive network-based flexible strain sensors with silicone rubber (SR) substrate. Combining MWCNTs with MXene as a conductive material has been shown to significantly improve the sensor performance, due to MXene's high conductivity properties that strengthen the MWCNT conductive pathway, increase sensitivity, and improve sensor stability.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Dept. of Retina and Vitreous, Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, India.
Purpose: To report a rare case of a Coats-like response developing after vitreoretinal surgery for proliferative diabetic retinopathy (PDR) and its successful management with retinal laser photocoagulation and adjunctive intravitreal steroids.
Case Description: A 52-year-old woman with a five-year history of type 2 diabetes mellitus and hypertension presented with decreased vision in the left eye (counting fingers at 1 m). Examination revealed high-risk PDR in both eyes, with a subtotal macula-off combined retinal detachment in the left eye.
MethodsX
June 2025
Department of Artificial Intelligence and Machine Learning, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Lavale, Pune, Maharashtra, India.
The increasing demand for soft robotic systems in agricultural, biomedical and other applications has driven the development of actuators that can mimic the flexibility and adaptability of human muscles. Several studies have explored the design and implementation of soft actuators for robotic applications, however, there is a need for soft actuators demonstrating delicate gripping capabilities but also excel in specific biomedical applications, such as therapeutic massaging. The objective of this work is to develop a multi-finger soft pneumatic actuator mimicking human fingers for Ayurvedic therapeutic massaging and gripping applications.
View Article and Find Full Text PDFJ Biomed Opt
June 2024
Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States.
Significance: Pulse oximeter measurements are commonly relied upon for managing patient care and thus often require human testing before they can be legally marketed. Recent clinical studies have also identified disparities in their measurement of blood oxygen saturation by race or skin pigmentation.
Aim: The development of a reliable bench-top performance test method based on tissue-simulating phantoms has the potential to facilitate pre-market assessment and the development of more accurate and equitable devices.
ACS Appl Mater Interfaces
January 2025
National Engineering Lab of Special Display Technology, Special Display and Imaging Technology Innovation Center of Anhui Province, Academy of Optoelectronic Technology, Hefei University of Technology, Hefei 230009, China.
Flexible sensors mimic the sensing ability of human skin, and have unique flexibility and adaptability, allowing users to interact with intelligent systems in a more natural and intimate way. To overcome the issues of low sensitivity and limited operating range of flexible strain sensors, this study presents a highly innovative preparation method to develop a conductive elastomeric sensor with a cracked thin film by combining polydimethylsiloxane (PDMS) with multiwalled carbon nanotubes (MCNT). This novel design significantly increases both the sensitivity and operating range of the sensor (strain range 0-50%; the maximum tensile sensitivity of this sensor reaches 4.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!