Objectives: The purpose of the study is to compare real ear to coupler difference (RECD) curves based on physical and psychophysical measures. For the physically measured RECD, the RECD was measured with real ear and coupler measurements for the ear simulator and HA1- and HA2 2-cc couplers. The psychophysically measured RECDs were derived from audiogram measures.
Design: RECDs were measured in 19 normally hearing subjects. The coupler measurement was done with the probe microphone and the coupler microphone itself. Psychophysically measured RECDs were derived for all subjects by measuring the audiogram in sound field and with an ER-3A insert phone.
Results: Reference data were obtained for the three coupler types. It was possible to derive the RECD curve with psychophysical methods. There was no overall statistical difference between the physically and psychophysically measured RECD curves for the HA2 2-cc coupler and the ear simulator. The standard deviation was, however, much higher for the psychophysically derived RECD, indicating that physically measured RECDs are more precise than psychophysically derived RECDs.
Conclusions: For the physical RECD measurements, the coupler microphone should be used for the coupler measurement. Physically measured RECDs were validated on group level by the reliable derivation of the RECD curve from audiogram measures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/AUD.0000000000000159 | DOI Listing |
PLoS One
December 2023
Department of Audiology and Speech Language Pathology, Mackay Medical College, New Taipei City, Taiwan.
Measurement of real-ear-to-coupler differentials (RECDs) is a critical part of the hearing aid (HA) verification process. This study examines the validity of reference RECD values preset by the HA analyzer, Audioscan RM500, for deaf-and-hard-of-hearing (DHH) children in Taiwan. RECD measurements were performed on 658 ears of DHH children.
View Article and Find Full Text PDFEar Hear
June 2023
Department of Audiology, Boys Town National Research Hospital, Omaha, Nebraska, USA.
Objectives: There is large variability in cervical and ocular vestibular evoked myogenic potential (c- and oVEMP) amplitudes. One potential source of variability is differences in ear canal shape and size. Real ear-to-coupler difference (RECD) values are used to measure the acoustic environment of an individual's ear canal.
View Article and Find Full Text PDFAm J Audiol
December 2022
VA Pittsburgh Healthcare System, PA.
Purpose: The real-ear-to-coupler difference (RECD) is a recommended measure for accurate hearing aid fittings, especially for pediatric populations. However, for adults, many clinicians question whether it is necessary.
Method: Hearing aids were fit on two groups of 85 older adults seen at a Veterans Administration audiology clinic.
Background: Pediatric hearing instrument fitting is optimally performed with individually obtained real-ear-to-coupler difference (RECD) measurements. If these measurements cannot be obtained, predicted values based on age are used. Recent evidence obtained from children aged 3-11 years suggests that head circumference (HC) may be a viable alternative or addition to age for use in RECD prediction.
View Article and Find Full Text PDFInt J Nanomedicine
December 2018
Scientific Research Center, China-Japan Union Hospital of Jilin University, Changchun, Jilin, P. R. China,
Background: Fluorescent carbon-based nanomaterials have promising properties such as biosensing, cell imaging, tracing and drug delivery. However, carbon dots (CDs) with specific inherent biological functions have not been investigated. Ginsenosides are the components with multiple bioactivities found in plants of the genus , which have attracted a lot of attention for their anticancer effect.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!