Introduction: Comparison between stainless steel staples and silk sutures for primary closure of skin in patients undergoing neck dissection, in context of rapid application, approximation of the skin edges, economy and aesthetics of the resultant scar.

Aim: (1) To compare surgical stainless steel staples and silk sutures for primary wound closure, with respect to presence/absence of wound infection and dehiscence (2) To compare the resultant scar following the two different methods of the closure at 3(rd) month postoperatively with the help of visual analog scale and analyze the result statistically

Design: This study was designed to compare skin closure using staples and silk sutures in patients undergoing neck dissection, using both methods in one-half of the same wound; thus each wound affording its own control.

Materials And Methods: The study was conducted on patients requiring collar line incision (high submandibular incision) with or without a cephalad extension of midline lower lip split incision for surgical access, who presented to the Department of Oral and Maxillo-Facial Surgery. (1) SAMPLE SIZE: 10 (2) STUDY DESIGN: Prospective Comparative study (3) Study duration: One and half years (4) Surgical stainless steel staples: Proximate Plus MD 35 W, Ethicon Endo Surgery (5) Sutures: 3-0 Ethiprime NW 5003, Non-Absorbable Surgical Suture, Mersilk-90 cm, Ethicon, (16 mm 3/8 circle cutting needle).

Conclusion: It was concluded that there is no significant difference between the scars observed in the regions of incision which underwent primary closure by two different methods, that is surgical stainless steel staples and 3-0 Mersilk Sutures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4374320PMC
http://dx.doi.org/10.4103/0976-237X.152938DOI Listing

Publication Analysis

Top Keywords

stainless steel
20
steel staples
20
staples silk
16
silk sutures
16
sutures primary
12
primary closure
12
patients undergoing
12
undergoing neck
12
neck dissection
12
surgical stainless
12

Similar Publications

Controlling Listeria monocytogenes and its associated biofilms in the food industry requires various disinfection techniques, including physical, chemical, and biological treatments. Biocides, owing to their ease of use, cost-effectiveness, dissolvability in water, and efficacy against a wide range of microorganisms, are frequently selected options. Nonetheless, concerns have been raised about their efficacy in controlling L.

View Article and Find Full Text PDF

Zeolite coatings are studied as molecular sieves for membrane separation, membrane reactors, and chemical sensor applications. They are also studied as anticorrosive films for metals and alloys, antimicrobial and hydrophobic films for heating, ventilation, and air conditioning, and dielectrics for semiconductor applications. Zeolite coatings are synthesized by hydrothermal, ionothermal, and dry-gel conversion approaches, which require high process temperatures and lengthy times (ranging from hours to days).

View Article and Find Full Text PDF

Introduction: Cephalosporins can trigger hypersensitivity reactions in certain individuals. Consequently, strict regulations restrict the production of non-beta-lactam substances during or after cephalosporin manufacturing. Dry chlorine dioxide gas (dClO), together with ultra-performance liquid chromatography Mass spectrometry/mass spectrometry (UPLC-MS/MS) detection methods, has emerged as a promising method for decontaminating cephalosporin compounds.

View Article and Find Full Text PDF

Early childhood caries (ECC), one of the most common health problems among children aged six years and below, is considered present when one or more surfaces of a tooth are decayed, missing, or filled. Not only does ECC cause pain for a long time, but it also has short- and long-term health consequences in children. In order to treat ECC, holistic management that includes preventive, restorative, and prosthetic intervention is necessary.

View Article and Find Full Text PDF

Unlike many conventional manufacturing techniques, 3D Printing/Additive Manufacturing (3DP/AM) fabrication creates builds with unprecedented degrees of structural and geometrical complexities. However, uncertainties in 3DP/AM processes and material attributes could cause geometric and structural quality issues in resulting builds and products. Evaluating the sensitivity of process parameters and material properties for process optimization, quality assessment, and closed-loop control is crucial in practice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!