Background: The mechanisms of improvement of left ventricular (LV) function with cardiac resynchronization therapy (CRT) are not yet elucidated. The aim of this study was to describe a new tool based on automatic quantification of the integrals of regional longitudinal strain signals and evaluate changes in LV strain distribution after CRT.
Methods: This was a retrospective observational study of 130 patients with heart failure before CRT device implantation and after 3 to 6 months of follow-up. Integrals of regional longitudinal strain signals (from the beginning of the cardiac cycle to strain peak [IL,peak] and to the instant of aortic valve closure [IL,avc]) were analyzed retrospectively with custom-made algorithms. Response to CRT was defined as a decrease in LV end-systolic volume of ≥15%.
Results: Responders (61%) and nonresponders (39%) showed similar baseline values of regional IL,peak and IL,avc. At follow-up, significant improvements of midlateral IL,peak and of midlateral IL,avc were noted only in responders. Midlateral IL,avc showed a relative increase of 151 ± 276% in responders, whereas a decrease of 33 ± 69% was observed in nonresponders. The difference between IL,avc and IL,peak (representing wasted energy of the LV myocardium) of the lateral wall showed a relative change of -59 ± 103% in responders between baseline and CRT, whereas in nonresponders, the relative change was 21 ± 113% (P = .009).
Conclusions: Strain integrals revealed changes between baseline and CRT in the lateral wall, demonstrating the beneficial effects of CRT on LV mechanics with favorable myocardial reverse remodeling.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.echo.2015.02.017 | DOI Listing |
Heart Rhythm
January 2025
Geisinger Heart Institute, Geisinger Wyoming Valley Medical Center, MC 36-10, 1000 E Mountain Blvd, Wilkes-Barre, PA 18711.
Micromachines (Basel)
January 2025
Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.
Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.
Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.
Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.
Nucl Med Commun
January 2025
Department of Cardiac and Vascular Diseases, St.John Paul II Hospital, Jagiellonian University Medical College, Krakow, Poland.
Objectives: Cardiac resynchronization therapy (CRT) is an intervention for heart failure patients with reduced ejection fraction who exhibit specific electrocardiographic indicators of electrical dyssynchrony. However, electrical dyssynchrony does not universally correspond to left ventricular mechanical dyssynchrony (LVMD). Gated single-photon emission computed tomography (SPECT) myocardial perfusion allows for the assessment of LVMD, yet its role in the CRT selection process remains debated.
View Article and Find Full Text PDFFront Cardiovasc Med
January 2025
Department of Cardiology, The First People's Hospital of Neijiang, Neijiang, China.
More than 1 million permanent pacemakers are implanted worldwide each year, half of which are in patients with high-grade atrioventricular block. Pacemakers provide adequate frequency support in the initial stage, but traditional right ventricular (RV) pacing may lead to or aggravate left ventricular dysfunction and arrhythmia. Several potential risk factors for heart failure and arrhythmias after pacemaker surgery have been identified, but their occurrence remains difficult to predict clinically.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!