Background: Numerous designs are used to the treatment of Early Onset Scoliosis. For example, a Thoraco-Lumbo-Sacral Orthosis (TLSO) is constructed using Polyethylene (PE). In addition, a series of castings has been implemented using cast material (3M, BSN Medical). The cast material has some significant advantages over the PE design including: growth preserving, improved compliance, decreased invasiveness, delaying or avoiding surgery, and the ability to allow the skin to breathe. However, the mechanical effectiveness of the cast material brace as compared to the TLSO is unknown, thus providing the objective of this study.

Methods: A total of 23 standardized tensile tests were performed on the Delta-Cast Soft(®) and 3M(TM) Scotchcast(TM) Plus Casting Tape in order to obtain mechanical properties (Young's and shear moduli and Poisson ratios). Using a radiograph of a thoracic spine, the size of twelve vertebrae and eleven intervertebral discs were measured and used to create a finite element spine model. Simulations using this model were used to establish mechanical loads which were then applied to finite element models of the TLSO and cast jacket. The thicknesses and number of material layers was varied in these models. Multiple simulations were performed.

Results: It was found that a 6.6.mm thick cast jacket made of Delta-Cast Soft(®) had a maximum deformation of 4.7 mm, a maximum stress of 2.9 MPa and a structural factor of safety of 5.71. On the other hand, a 4 mm thick jacket made of PE had a maximum deformation of 2 mm, a maximum stress of 8.9 MPa and a structural factor of safety of 2.70. The cast jacket was 3.5 times lighter and had a material of cost 1/5 of the PE brace.

Conclusions: Based on the results, either design will generate the proper constraint forces to maintain spinal correction. But, based on the design parameters (thickness, mechanical properties, structural factor of safety and cost) the brace made of cast material, though slightly thicker has superior structural and cost benefits. Thus, from the biomechanical point of view, the cast brace is more efficient than the PE brace.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4331733PMC
http://dx.doi.org/10.1186/1748-7161-10-S2-S15DOI Listing

Publication Analysis

Top Keywords

cast material
20
cast jacket
12
structural factor
12
factor safety
12
cast
9
delta-cast soft®
8
mechanical properties
8
finite element
8
maximum deformation
8
deformation maximum
8

Similar Publications

Background: The success of a restoration largely depends on the quality of its fit. This study aimed to investigate the fit quality of monolithic zirconia veneers (MZVs) produced through traditional and digital workflows.

Methods: A typodont maxillary right central incisor was prepared.

View Article and Find Full Text PDF

Magnetocaloric high-entropy alloys (HEAs) have recently garnered significant interest owing to their potential applications in magnetic refrigeration, offering a wide working temperature range and large refrigerant capacity. In this study, we thoroughly investigated the structural, magnetic, and magnetocaloric properties of equiatomic GdDyHoErTm HEAs. The as-cast alloy exhibits a single hexagonal phase, a randomly distributed grain orientation, and complex magnetism.

View Article and Find Full Text PDF

Soft materials underpin many domains of science and engineering, including soft robotics, structured fluids, and biological and particulate media. In response to applied mechanical, electromagnetic or chemical stimuli, such materials typically change shape, often dramatically. Predicting their structure is of great interest to facilitate design and mechanistic understanding, and can be cast as an optimization problem where a given energy function describing the physics of the material is minimized with respect to the shape of the domain and additional fields.

View Article and Find Full Text PDF

Currently, the main limitations of Pd-coated Nb-TiFe dual-phase alloys include insufficient hydrogen permeability, susceptibility to hydrogen embrittlement (HE), and poor tolerance of HS poisoning. To address these issues, this study proposes a series of improvements. First, a novel NbTiFe alloy composed of a well-aligned Nb-TiFe eutectic was successfully prepared using directional solidification (DS) technology.

View Article and Find Full Text PDF

Objective: This study aimed to assess and compare the internal fit of custom-made posts and cores fabricated using digital impressions (DI) and conventional vinyl polysiloxane (VPS) impressions in restorative dentistry.

Materials And Methods: A typodont tooth model, simulating the anatomy of the root canal of a central incisor, was utilized for the study. Two groups were formed, Group A and Group B, and each group provided a total of 18 impressions of two types: DIs and VPS impressions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!