Background: Axial vertebral rotation (AVR) is one of the important parameters to evaluate the severity and predict the progression of scoliosis. However, the AVR measurements on radiographs may underestimate its actual value. This pilot study investigated a new three-dimensional (3D) ultrasound method to measure AVR.
Methods: Three cadaveric vertebrae T7, L1, and L3 were scanned with a 3D medical ultrasound system. Nine sets of ultrasound data, the vertebral rotation from 0 to 40° with 5° increments, were recorded from each vertebra. An in-house program was developed to reconstruct and measure the 3D vertebral images. The rotation of each reconstructed vertebra was determined by the angle between the line going through the centres of either laminae (L-L) or transverse processes (TP-TP) and a reference vertical plane. Three raters measured the rotation in 3 sessions, in which they used the mouse pointer to select the L-L or TP-TP according to their knowledge of vertebral anatomy. The program detected the 3D coordinates of these points and calculated the AVR. The intra-class correlation coefficients (ICCs) were used to calculate the intra-reliability and inter-reliability. The mean absolute difference (MAD±SD) and the range of difference (RD) between the actual values and the average measurements of each rater were computed to evaluate the accuracy of methods.
Results: When rotation was greater than 30° for both L1 and L3, all raters found it difficult to determine one of the lamina areas due to the lack of ultrasound information in an area behind the spinous process. Therefore, the corresponding measurements were excluded. The ICC values of the intra-reliability (L-L, TP-TP) for the three raters were (0.987, 0.991), (0.989, 0.998) and (0.997, 1.000), respectively; meanwhile, the inter-reliability were 0.991 for (L-L) and 0.992 for (TP-TP). All ICC values were greater than 0.98 indicating both methods were highly reliable. The MAD±SD values (L-L, TP-TP) for the three raters were (1.5±0.3°, 1.2±0.2°), (1.6±0.3°, 1.3±0.3°), and (1.7±0.5°, 0.9±0.2°), respectively. The RD (L-L, TP-TP) were (0-4.5°, 0-3.5°), (0-5.1°, 0-4.3°), and (0-5.1°, 0-2.8°) for the three raters, respectively.
Conclusions: The (L-L) and (TP-TP) methods could be used to measure AVR reliability from the 3D ultrasound images.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4331767 | PMC |
http://dx.doi.org/10.1186/1748-7161-10-S2-S7 | DOI Listing |
Dalton Trans
October 2023
Research School of Chemistry, Australian National University, Canberra, ACT, Australia.
The μ-carbido complex [WPt(μ-C)Br(CO)(PPh)(Tp*)] (Tp = hydrotris(dimethylpyrazolyl)borate) undergoes substitution of one phosphine ligand with isonitriles to afford complexes [WPt(μ-C)Br(CNR)(CO)(PPh)(Tp*)] (R = Bu, CHMe-2,6, CHMe-2,4,6). For aryl but not alkyl isocyanides disubstitution follows to afford [WPt(μ-C)Br(CNR)(CO)(Tp*)] (R = CHMe-2,6, CHMe-2,4,6). The bis(isonitrile) derivatives, including [WPt(μ-C)Br(CNBu)(CO)(Tp*)], may also be prepared from the reactions of -[Pt(CNR)] with [W(CBr)(CO)(Tp*)].
View Article and Find Full Text PDFScoliosis
May 2015
Department of Biomedical Engineering, University of Alberta, Edmonton, Canada ; Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Canada.
Background: Axial vertebral rotation (AVR) is one of the important parameters to evaluate the severity and predict the progression of scoliosis. However, the AVR measurements on radiographs may underestimate its actual value. This pilot study investigated a new three-dimensional (3D) ultrasound method to measure AVR.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!