Clinical value of whole-body magnetic resonance imaging in health screening of general adult population.

Radiol Oncol

Department of Diagnostic and Interventional Radiology, Caritasklinikum Saarbrücken St. Theresia, Academic Teaching Hospital of Saarland University, Saarbrücken, Germany.

Published: March 2015

Background: Whole-body magnetic resonance imaging (WB-MRI) and angiography (WB-MRA) has become increasingly popular in population-based research. We evaluated retrospectively the frequency of potentially relevant incidental findings throughout the body.

Materials And Methods: 22 highly health-conscious managers (18 men, mean age 47±9 years) underwent WB-MRI and WB-MRA between March 2012 and September 2013 on a Discovery MR750w wide bore 3 Tesla device (GE Healthcare) using T1 weighted, short tau inversion recovery (STIR) and diffusion weighted imaging (DWI) acquisitions according to a standardized protocol.

Results: A suspicious (pararectal) malignancy was detected in one patient which was confirmed by an endorectal sonography. Incidental findings were described in 20 subjects, including hydrocele (11 patients), benign bony lesion (7 patients) and non-specific lymph nodes (5 patients). Further investigations were recommended in 68% (ultrasound: 36%, computed tomography: 28%, mammography: 9%, additional MRI: 9%). WB-MRA were negative in 16 subjects. Vascular normal variations were reported in 23%, and a 40% left proximal common carotid artery stenosis were described in one subject.

Conclusions: WB-MRI and MRA lead to the detection of clinically relevant diseases and unexpected findings in a cohort of healthy adults that require further imaging or surveillance in 68%. WB-MR imaging may play a paramount role in health screening, especially in the future generation of (epi)genetic based screening of malignant and atherosclerotic disorders. Our study is the first which involved a highly selected patient group using a high field 3-T wide bore magnet system with T1, STIR, MRA and whole-body DWI acquisitions as well.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4362601PMC
http://dx.doi.org/10.2478/raon-2014-0031DOI Listing

Publication Analysis

Top Keywords

whole-body magnetic
8
magnetic resonance
8
resonance imaging
8
health screening
8
incidental findings
8
wide bore
8
dwi acquisitions
8
imaging
5
clinical whole-body
4
imaging health
4

Similar Publications

The noninvasive prenatal test (NIPT) for genetic screening has been adopted globally as an alternative to first-trimester and quad screening due to its high sensitivity and specificity. NIPT involves detecting and processing foreign fetal DNA in maternal circulation to screen for fetal aneuploidy. An incidental consequence of this process is the detection of foreign tumor cell DNA in maternal circulation in otherwise asymptomatic patients.

View Article and Find Full Text PDF

Advanced Automated Model for Robust Bone Marrow Segmentation in Whole-body MRI.

Acad Radiol

January 2025

Division of Radiology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany (F.B., M.G., H.P.S., S.D.); Diagnostic and Interventional Radiology, University Hospital Heidelberg, 69120 Heidelberg, Germany (T.F.W., M.W.).

Rationale And Objectives: To establish an advanced automated bone marrow (BM) segmentation model on whole-body (WB-)MRI in monoclonal plasma cell disorders (MPCD), and to demonstrate its robust performance on multicenter datasets with severe myeloma-related pathologies.

Materials And Methods: The study cohort comprised multi-vendor, multi-protocol imaging data acquired with varying field strength across 8 different centers. In total, 210 WB-MRIs of 207 MPCD patients were included.

View Article and Find Full Text PDF

Background: Deep learning (DL)-based adipose tissue segmentation methods have shown great performance and efficacy for adipose tissue distribution analysis using magnetic resonance (MR) images, an important indicator of metabolic health and disease. The aim of this study was to evaluate the reproducibility of whole-body adipose tissue distribution analysis using proton density fat fraction (PDFF) images at different MR strengths.

Methods: A total of 24 volunteers were imaged using both 1.

View Article and Find Full Text PDF

Improving Image Quality and Decreasing SAR With High Dielectric Constant Pads in 3 T Fetal MRI.

J Magn Reson Imaging

January 2025

Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.

Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.

Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.

Study Type: Prospective.

View Article and Find Full Text PDF

Background: The objective of this report is to present a case of two cervical spine artificial discs (Bryan Cervical Disk) that completely disappeared within 6 months as a result of a high-energy trauma more than 10 years after the initial surgery. Implant dislocation is a known complication in artificial cervical disc replacement. However, this report presents the case of an exceptional migration path with esophageal ingrowth and rectal excretion, not only for one artificial disc but for two at different times It highlights the need for long-term follow-up examinations after artificial cervical disc arthroplasty (ACDA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!