A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

End tidal-to-arterial CO2 and O2 gas gradients at low- and high-altitude during dynamic end-tidal forcing. | LitMetric

End tidal-to-arterial CO2 and O2 gas gradients at low- and high-altitude during dynamic end-tidal forcing.

Am J Physiol Regul Integr Comp Physiol

Centre for Heart, Lung, and Vascular Health, School of Health and Exercise Science, University of British Columbia, Kelowna, Canada; and

Published: June 2015

We sought to characterize and quantify the performance of a portable dynamic end-tidal forcing (DEF) system in controlling the partial pressure of arterial CO2 (Pa(CO2)) and O2 (Pa(O2)) at low (LA; 344 m) and high altitude (HA; 5,050 m) during an isooxic CO2 test and an isocapnic O2 test, which is commonly used to measure ventilatory and vascular reactivity in humans (n = 9). The isooxic CO2 tests involved step changes in the partial pressure of end-tidal CO2 (PET(CO2)) of -10, -5, 0, +5, and +10 mmHg from baseline. The isocapnic O2 test consisted of a 10-min hypoxic step (PET(O2) = 47 mmHg) from baseline at LA and a 5-min euoxic step (PET(O2) = 100 mmHg) from baseline at HA. At both altitudes, PET(O2) and PET(CO2) were controlled within narrow limits (<1 mmHg from target) during each protocol. During the isooxic CO2 test at LA, PET(CO2) consistently overestimated Pa(CO2) (P < 0.01) at both baseline (2.1 ± 0.5 mmHg) and hypercapnia (+5 mmHg: 2.1 ± 0.7 mmHg; +10 mmHg: 1.9 ± 0.5 mmHg). This P(a)-PET(CO2) gradient was approximately twofold greater at HA (P < 0.05). At baseline at both altitudes, PET(O2) overestimated Pa(O2) by a similar extent (LA: 6.9 ± 2.1 mmHg; HA: 4.5 ± 0.9 mmHg; both P < 0.001). This overestimation persisted during isocapnic hypoxia at LA (6.9 ± 0.6 mmHg) and during isocapnic euoxia at HA (3.8 ± 1.2 mmHg). Step-wise multiple regression analysis, on the basis of the collected data, revealed that it may be possible to predict an individual's arterial blood gases during DEF. Future research is needed to validate these prediction algorithms and determine the implications of end-tidal-to-arterial gradients in the assessment of ventilatory and/or vascular reactivity.

Download full-text PDF

Source
http://dx.doi.org/10.1152/ajpregu.00425.2014DOI Listing

Publication Analysis

Top Keywords

mmhg baseline
12
dynamic end-tidal
8
end-tidal forcing
8
partial pressure
8
isooxic co2
8
isocapnic test
8
step peto2
8
tidal-to-arterial co2
4
co2 gas
4
gas gradients
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!