The (1)H-(19) F heteronuclear NMR experiments were achieved using the conventional spectrometer equipped with a single high band amplifier and a (1)H/(19)F/(13) C double-tuned probe. Although double high band amplifiers are generally required to perform such experiments, a simple modification of pathway in the conventional spectrometer was capable of acquiring various (1)H-(19)F heteronuclear spectra. The efficiency of the present technique was demonstrated in an application for (19)F{(1)H} and (1)H{(19)F} saturation transfer difference experiments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mrc.4210 | DOI Listing |
Biosens Bioelectron
December 2024
School of Science and Engineering, Shenzhen Institute of Aggregate Science and Technology, The Chinese University of Hong Kong, Shenzhen, Guangdong 518172, China.
Conventional fluorescent probes with weak fluorescence signals and aggregation-caused quenching effect limits in biomarkers detection, thus requiring many labeled target molecules to combine their output to achieve higher signal-to noise. Here, we harness a "immune-sandwich" based affinity sensor with development of ultrabright aggregation-induced emission luminogens (AIEgens) microspheres as signal reporter. The fabricated sensor can simultaneously permit triple detection formats by naked eye, spectrum, and computer vision counting (termed "NeSCV sensor").
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
December 2024
School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China.
Tandem mass spectrometry (MS) is one of the most effective methods to obtain the structures of organic molecules, enabling the observation of multigenerational ion fragments. Collision-induced dissociation (CID) is currently the most mature technique for mass spectrometry analysis. Ion trap mass spectrometry (ITMS) is favored for on-site detection field, due to its ability of MS analysis with a single trap and its small size.
View Article and Find Full Text PDFJ Magn Reson
December 2024
Bridge12 Magnetic Resonance, 11 Michigan Drive, Natick, MA 01760, USA. Electronic address:
We present a fully automated cryogenic sample insertion and ejection system for use with low-temperature EPR probes. We show how the system can be implemented on a conventional EPR spectrometer and that ejection and insertion is reliably possible at temperatures down to 10 K. Furthermore, we investigate the glass properties of a 0.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Centre of Polymer Systems, University Institute, Tomas Bata University in Zlin, třída Tomáše Bati 5678, 76001 Zlín, Czech Republic.
Bone tissue engineering demands advanced biomaterials with tailored properties. In this regard, composite scaffolds offer a strategy to integrate the desired functionalities. These scaffolds are expected to provide sufficient cellular activities while maintaining the required strength necessary for the bone repair for which they are intended.
View Article and Find Full Text PDFMicroplastics (MPs), less than 5 mm in length, have become a major environmental issue due to their hazardous physical and chemical properties. The research investigated 54 sediment samples collected from three different zones of the beaches, namely the wrack line, beach face, and swash zone. This study aims to enumerate the number and polymeric variety of microplastics found in beach sediments from coastal islands of Bangladesh, including Sandwip, Kutubdia, and Saint Martin's Island in the northeastern Bay of Bengal.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!