Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Long gap esophageal atresia remains a significant treatment challenge. We aimed to create the first large animal model of long gap esophageal atresia to test a degradable esophageal lengthening device.
Methods: The distal esophagus was divided 2 cm above the gastroesophageal junction in 6 minipigs. A polycaprolactone (PCL) spring device was secured inside the distal esophageal segment, and the end was oversewn. Nonexpanding PCL tubes served as controls. An esophagogastric anastomosis was created to restore continuity. After 4 weeks, the distal esophageal pouch was analyzed.
Results: The distal esophageal pouch of experimental animals increased in length from 1.9 to 4.5 cm. Control animals demonstrated no change. When comparing lengthened to native esophagus, there was no difference in the thickness of muscularis mucosa or muscularis propria. Mechanically lengthened esophagus showed mild to moderate superficial inflammation and fibrosis. There were no differences in the number of myenteric or submucosal ganglia.
Conclusion: We created the first porcine model of long gap esophageal atresia and lengthened the distal esophagus with an internally placed device. This model may be used to explore novel therapies in the management of long gap esophageal atresia.