QCT/FEA predictions of femoral stiffness are strongly affected by boundary condition modeling.

Comput Methods Biomech Biomed Engin

a Division of Engineering, Mayo Clinic, 200 First St SW, Rochester , MN 55905 , USA.

Published: June 2016

Quantitative computed tomography-based finite element models of proximal femora must be validated with cadaveric experiments before using them to assess fracture risk in osteoporotic patients. During validation, it is essential to carefully assess whether the boundary condition (BC) modeling matches the experimental conditions. This study evaluated proximal femur stiffness results predicted by six different BC methods on a sample of 30 cadaveric femora and compared the predictions with experimental data. The average stiffness varied by 280% among the six BCs. Compared with experimental data, the predictions ranged from overestimating the average stiffness by 65% to underestimating it by 41%. In addition, we found that the BC that distributed the load to the contact surfaces similar to the expected contact mechanics predictions had the best agreement with experimental stiffness. We concluded that BC modeling introduced large variations in proximal femora stiffness predictions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4583333PMC
http://dx.doi.org/10.1080/10255842.2015.1006209DOI Listing

Publication Analysis

Top Keywords

boundary condition
8
condition modeling
8
proximal femora
8
experimental data
8
average stiffness
8
stiffness
6
qct/fea predictions
4
predictions femoral
4
femoral stiffness
4
stiffness boundary
4

Similar Publications

To measure the electroacoustic parameters of transducers in the continuous sound field in a limited water area, a reciprocity calibration method of hydrophones using a spatial sampling average method in a non-anechoic tank was developed. The sound propagation in the non-anechoic tank under the impedance boundary condition, with a sound source producing continuous sound, is introduced based on the Helmholtz equation and Green's function. The reciprocity constant is given using the spatial sampling average sound pressure, and the three-transducer reciprocity calibration procedure was established.

View Article and Find Full Text PDF

3D printing is a popular and cost-effective method for producing lightweight engineering parts with enhanced characteristics and detailed prototypes. Nevertheless, the quality of the print can be diminished by the selection of improper parameter settings. This investigation explored the impact of printing factors on the tensile behavior of polylactic acid (PLA) and Acrylonitrile Butadiene Styrene (ABS) specimens.

View Article and Find Full Text PDF

Inductively coupled plasma mass spectrometry (ICP-MS) has demonstrated significant capabilities in the analysis of single events, such as single cells and particles. Researchers have been actively pursuing innovations in ICP-MS sample introduction systems to enhance their transport efficiency, as this is critical for ensuring the accuracy of single-event analysis. However, the majority of prior studies have relied heavily on empirical approaches, with limited attention given to the individual characteristics of particles from a theoretical perspective and a lack of efficient manufacturing tools for optimizing related components.

View Article and Find Full Text PDF

Analysis of the haemodynamic changes caused by surgical and transcatheter aortic valve replacements by means fluid-structure interaction simulations.

Comput Biol Med

January 2025

UCL Mechanical Engineering, University College London, UK; Ri.MED Foundation, Palermo, Italy; University of Palermo, Department of Engineering, Palermo, Italy. Electronic address:

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.

View Article and Find Full Text PDF

This study analyzes the influences of surface reactions on the natural convective flow, temperature, and oxygen concentration distributions in vertically placed multilayered cavities. A mathematical model for this problem is formulated with proper boundary conditions. At first, the governing equations are made dimensionless using the variable transformations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!