Thrombosis in the right atrium or ventricle is a rare complication of permanent endocardial pacing in adults. To the best of our knowledge, this complication has not been previously reported at all in the pediatric age group. We report on a case of a 7-year-old boy who had large left ventricular thrombi that occurred during permanent endocardial electrical stimulation. Subsequent pulmonary emboli complicated congestive heart failure in this patient. As a diagnostic approach, echocardiography and pulmonary perfusion scintigraphy were used. We comment on possible causes of this serious complication and suggest hemorrheological and platelet activation studies in patients with permanent endocardial pacing.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.1985.tb05745.xDOI Listing

Publication Analysis

Top Keywords

permanent endocardial
16
endocardial pacing
12
ventricular thrombosis
4
permanent
4
thrombosis permanent
4
endocardial
4
pacing pediatric
4
pediatric patient
4
patient hemorrheological
4
hemorrheological disorders
4

Similar Publications

Article Synopsis
  • Tricuspid valve pathology is common and presents challenges for mechanical tricuspid valve replacement, particularly when implanting a permanent pacemaker due to risks like valve damage and lead fractures.
  • Epicardial leads, while an option, are not ideal for patients with past thoracotomies due to surgical requirements.
  • This case report showcases successful left ventricular (LV) pacing through the coronary sinus in a 30-year-old woman, proving it to be a safe and effective alternative method for pacemaker implantation without additional invasive procedures.
View Article and Find Full Text PDF

We present a case of successful implantation of a cardioverter-defibrillator (ICD) using combined technique in a child with Timothy's syndrome. Due to high risk of sudden cardiac death (SCD) such patients often need ICD for primary or secondary prevention but implantation technique in young children remains controversial. The subcutaneous cardioverter-defibrillators could be an option in some cases, however, reliable cardiac pacing should be implemented for patients with bradyarrhythmias.

View Article and Find Full Text PDF

: The number of cardiac pacemakers being used has increased in recent decades, and this increase has led to a rise in device-related complications, requiring percutaneous device extraction. Our aim was to present our single-center clinical experience in percutaneous lead extractions. : We analyzed an observational retrospective cohort study of 93 patients for the transvenous removal of a total of 163 endocardial leads.

View Article and Find Full Text PDF

Feasibility of epicardial implantation of medtronic 3830 lead in a pediatric patient : case report.

J Cardiothorac Surg

July 2024

Department of Cardiovascular Surgery, Cheng Du Shang Jin Nan Fu Hospital, West China Hospital, Sichuan University, Sinchuan Province, 610041, Shandong, China.

Background: High-grade atrioventricular block is the primary reason for epicardial permanent pacemaker implantation during the perioperative period in patients with congenital heart disease. Due to the smaller diameter of venous vessels in children, epicardial permanent pacemaker implantation is usually a preferred choice, we report one pediatric patient who received epicardial permanent pacemaker implantation using a new approach.

Case Presentation: We present the case of a 2-year-old girl who underwent the modified Konno procedure and Pulmonary valvuloplasty surgery and presented after surgery with a High-grade atrioventricular block.

View Article and Find Full Text PDF

Bifocal coronary sinus pacing and transcatheter tricuspid valve-in-valve implantation: an innovative combined approach.

Future Cardiol

April 2024

University Cardiology Unit, Interdisciplinary Department of Medicine, "Aldo Moro" University School of Medicine, Polyclinic University Hospital, Piazza Giulio Cesare 11, Bari 70124, Italy.

Article Synopsis
  • * The placement of the pacemaker lead in the right ventricle can interfere with the function of the implanted prosthetic valve, potentially causing its dysfunction and requiring alternative pacing locations.
  • * The authors describe a novel combined procedure involving the implantation of two leads in the coronary sinus for effective pacing, alongside a transcatheter procedure to replace a malfunctioning tricuspid bioprosthesis in a young patient.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!