A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analytical method development for the determination of emerging contaminants in water using supercritical-fluid chromatography coupled with diode-array detection. | LitMetric

An analytical method using supercritical-fluid chromatography coupled with diode-array detection for the determination of seven emerging contaminants-two pharmaceuticals (carbamazepine and glyburide), three endocrine disruptors (17α-ethinyl estradiol, bisphenol A, and 17β-estradiol), one bactericide (triclosan), and one pesticide (diuron)-was developed and validated. These contaminants were chosen because of their frequency of use and their toxic effects on both humans and the environment. The optimized chromatographic separation on a Viridis BEH 2-EP column achieved baseline resolution for all compounds in less than 10 min. This separation was applied to environmental water samples after sample preparation. The optimized sample treatment involved a preconcentration step by means of solid-phase extraction using C18-OH cartridges. The proposed method was validated, finding recoveries higher than 94 % and limits of detection and limits of quantification in the range of 0.10-1.59 μg L(-1) and 0.31-4.83 μg L(-1), respectively. Method validation established the proposed method to be selective, linear, accurate, and precise. Finally, the method was successfully applied to environmental water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-015-8581-xDOI Listing

Publication Analysis

Top Keywords

analytical method
8
determination emerging
8
supercritical-fluid chromatography
8
chromatography coupled
8
coupled diode-array
8
diode-array detection
8
applied environmental
8
environmental water
8
water samples
8
proposed method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!