A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of flexible substrates for clinical translation of laser-generated shockwave therapy. | LitMetric

Bacteria biofilms in chronically infected wounds significantly increase the burden of healthcare costs and resources for patients and clinics. Because biofilms are such an effective barrier to standard antibiotic treatment, new methods of therapy need to be developed to combat these infections. Our group has demonstrated the potential of using Laser Generated Shockwaves as a potential therapy to mechanically disrupt the bacterial biofilms covering the wound. Previous studies have used rigid silica glass as the shockwave propagation medium, which is not compatible with the intended clinical application. This paper describes the exploration of five candidate flexible plastic films to replace the glass substrate. Each material measured 0.254 mm thick and was used to generate shockwaves of varying intensities. Shockwave characterization was performed using a high-speed Michelson displacement interferometer and peak stress values obtained in the flexible substrates were compared to glass using one-way nested Analysis of Variance and Tukey HSD post-hoc analysis. Results demonstrate statistically significant differences between substrate material and indicate that polycarbonate achieves the highest peak stress for a given laser fluence suggesting that it is optimal for clinical applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4361437PMC
http://dx.doi.org/10.1364/BOE.6.000827DOI Listing

Publication Analysis

Top Keywords

flexible substrates
8
substrate material
8
peak stress
8
analysis flexible
4
substrates clinical
4
clinical translation
4
translation laser-generated
4
laser-generated shockwave
4
shockwave therapy
4
therapy bacteria
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!