Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2015.03.087 | DOI Listing |
Eur Heart J Case Rep
January 2025
Cardiology Department, Loyola University Medical Center, 2160 S 1st Ave, Maywood, IL 60153-3328, USA.
Background: Immune checkpoint inhibitors (ICIs) are effective antineoplastic agents but can cause adverse effects in many organ systems. Cardiovascular toxicities include arrhythmias, myocarditis, heart failure, takotsubo syndrome, pericarditis, coronary artery disease, and vasculitis.
Case Summary: A 66-year-old woman with Stage 3C2 endometrial carcinoma presented for her second cycle of pembrolizumab, carboplatin, and paclitaxel.
Eur Heart J Case Rep
January 2025
1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.
Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications.
Case Summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection.
Cureus
December 2024
Department of Neurosurgery, Dr. Sa'ad AL-Witri Hospital for Neurosciences, Baghdad, IRQ.
Orbital arteriovenous fistulas (AVFs) are rare vascular malformations that can cause severe ocular complications. This review evaluates the effectiveness of treatment strategies, focusing on post-treatment recovery and recurrence. A systematic review was conducted using PubMed and Scopus with no date restrictions.
View Article and Find Full Text PDFJ Arrhythm
December 2024
THEMA Consulting Pty Ltd Milsons Point New South Wales Australia.
Background: Micra™ VR Transcatheter Pacing System (Micra VR) is a single-chamber transcatheter leadless pacemaker. Absence of leads and subcutaneous pocket reduces or completely eliminates the risk of complications associated with the conventional transvenous pacemakers (TVPM). When compared with TVPM, the leadless technology provides a quicker postimplantation recovery and causes less cosmetic concerns/discomfort providing better patient experiences in the long run.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
October 2024
Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, Hackensack, New Jersey, USA.
A large proportion of patients referred for transcatheter tricuspid valve intervention (TTVI) will have the presence of a cardiac implantable electronic device (CIED). In such patients, surgical correction of tricuspid regurgitation (TR) is associated with high rates of morbidity and mortality. Transvenous lead extraction (TLE) could potentially ameliorate CIED-induced TR; however, it carries inherent risks and frequently does not result in TR improvement.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!