This study describes the preclinical development of a matrix-type silicone elastomer vaginal ring device designed to provide controlled release of UC781, a non-nucleoside reverse transcriptase inhibitor. Testing of both human- and macaque-sized rings in a sink condition in vitro release model demonstrated continuous UC781 release in quantities considered sufficient to maintain vaginal fluid concentrations at levels 82-860-fold higher than the in vitro IC50 (2.0 to 10.4 nM) and therefore potentially protect against mucosal transmission of HIV. The 100-mg UC781 rings were well tolerated in pig-tailed macaques, did not induce local inflammation as determined by cytokine analysis and maintained median concentrations in vaginal fluids of UC781 in the range of 0.27 to 5.18 mM during the course of the 28-day study. Analysis of residual UC781 content in rings after completion of both the in vitro release and macaque pharmacokinetic studies revealed that 57 and 5 mg of UC781 was released, respectively. The pharmacokinetic analysis of a 100-mg UC781 vaginal ring in pig-tailed macaques showed poor in vivo-in vitro correlation, attributed to the very poor solubility of UC781 in vaginal fluid and resulting in a dissolution-controlled drug release mechanism rather than the expected diffusion-controlled mechanism.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13346-015-0216-4DOI Listing

Publication Analysis

Top Keywords

vaginal ring
12
uc781
8
vitro release
8
vaginal fluid
8
100-mg uc781
8
pig-tailed macaques
8
uc781 vaginal
8
vaginal
6
release
5
lack vitro-in
4

Similar Publications

Background: The intrauterine device (IUD) is a highly effective form of long-acting reversible contraception, widely recognized for its convenience and efficacy. Despite its benefits, many patients report moderate to severe pain during and after their IUD insertion procedure. Furthermore, reports suggest significant variability in pain control medications, including no adequate pain medication.

View Article and Find Full Text PDF

Background: This study aims to investigate adverse drug reaction signals associated with coagulopathies through data mining using the Adverse Event Reporting System (FAERS) of the US Food and Drug Administration. Prompt identification of high-risk drugs provides a valuable basis for enhancing clinical drug safety.

Methods: The adverse event reports related to coagulopathies from Q1 2004 to Q2 2024 were extracted from the ASCII data packages in FAERS.

View Article and Find Full Text PDF

Migrated intra-uterine device to infra-umbilical skin: a rare case report.

BMC Womens Health

December 2024

Department of Obstetrics and Gynecology, College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia.

Introduction: IUDs are effective, reversible and safe methods of contraception. The mechanism of action of IUDs as a group is inducing endometrial atrophy, apoptosis, altering tubal motility; preventing sperm permeability, fertilization, and implantation. Complications of IUD include menstrual disturbance, pelvic pain, and increased risk of ectopic pregnancy with contraceptive failure, device expulsion, uterine perforation or transmural migration with misplacement of the device.

View Article and Find Full Text PDF

Surgical Treatment of Peripartum Pelvic Ring Injury: Case Report.

Rev Bras Ortop (Sao Paulo)

November 2024

Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil.

During the gestational period, the pubic symphysis dilates for vaginal delivery. However, exacerbated widening may indicate ligament injury and pelvic instability, resulting in significant pain complaints. This uncommon condition is called peripartum pubic symphysis disjunction (PPSD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!