A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluating the dual target binding capabilities of immobilized aptamers using flow cytometry. | LitMetric

Evaluating the dual target binding capabilities of immobilized aptamers using flow cytometry.

Biointerphases

School of Materials Science and Engineering, Georgia Institute of Technology, 771 Ferst Dr. NW, Atlanta, Georgia 30332; Wallace C. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 313 Ferst Dr., Atlanta, Georgia 30332; and Petit Institute of Bioengineering and Bioscience, Georgia Institute of Technology, 315 Ferst Dr., Atlanta, Georgia 30332.

Published: March 2015

In the current study, the authors quantify the binding activity of particle-immobilized DNA aptamers to their nucleotide and non-nucleotide targets. For the purposes of this work, DNA and vascular endothelial growth factor (VEGF) binding analysis was carried out for VEGF-binding aptamers and compared to that of an ampicillin-binding aptamer as well as a non-aptamer DNA probe. Binding analysis followed incubation of one target type, coincubation of both DNA and VEGF targets, and serial incubations of each target type. Moreover, recovery of aptamer binding activity following displacement of the DNA target from aptamer:DNA duplexes was also explored. Flow cytometry served as the quantitative tool to directly monitor binding events of both the DNA target and protein target to the various aptamer and non-aptamer functionalized particles. The current work demonstrates how processing steps such as annealing and binding history of particle-immobilized aptamers can affect subsequent binding activity. To this end, the authors demonstrate the ability to fully recover DNA target binding activity capabilities and to partially recover protein target binding activity.

Download full-text PDF

Source
http://dx.doi.org/10.1116/1.4915107DOI Listing

Publication Analysis

Top Keywords

binding activity
20
target binding
12
dna target
12
binding
10
target
8
flow cytometry
8
binding analysis
8
target type
8
protein target
8
dna
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!