Biometric and intraocular pressure change after cataract surgery.

Optom Vis Sci

*MD Department of Ophthalmology, Adiyaman University, School of Medicine (SB, AS, MC, MG); and Department of Ophthalmology, Adiyaman University, Education and Research Hospital (BB), Adiyaman, Turkey.

Published: April 2015

Purpose: To evaluate changes in ocular biometric parameters with optical biometry and intraocular pressure (IOP) by Goldmann tonometry after uneventful phacoemulsification in normotensive eyes.

Methods: This prospective study was composed of 117 eyes of 117 patients who had undergone uncomplicated phacoemulsification and foldable intraocular lens implantation. The measurements were obtained preoperatively and 1 month postoperatively. Axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter (PD), and lens thickness were measured by the LenStar optical biometer, and IOP was measured by Goldmann applanation tonometry. The relationships between IOP change and ocular biometric parameters were evaluated.

Results: Mean age was 64.73 ± 10.83 years; 45 patients were women (38.46%) and 72 patients were men (61.54%). Comparing preoperative and postoperative 1-month measurements, the mean AL, PD, and IOP decreased (p < 0.01), whereas ACD (p < 0.01) and CCT (p > 0.05) increased. Intraocular pressure change correlated positively with AL change (p < 0.05) and PD change (p < 0.05) and preoperative IOP (p < 0.01) and preoperative CCT (p < 0.05). Anterior chamber depth change correlated positively with preoperative ACD (p < 0.01) and negatively with preoperative PD (p < 0.05). Pupil diameter change positively correlated with preoperative PD (p < 0.01). Regression analyses showed that preoperative IOP significantly associated with postoperative IOP reduction according to the standardized coefficient beta (-0.649).

Conclusions: Anterior segment morphometry changed and IOP decreased after phacoemulsification. The preoperative IOP may be the best parameter for estimating postoperative IOP reduction.

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000553DOI Listing

Publication Analysis

Top Keywords

intraocular pressure
12
preoperative iop
12
iop
10
pressure change
8
ocular biometric
8
biometric parameters
8
anterior chamber
8
chamber depth
8
pupil diameter
8
preoperative
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!