A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Denominator doesn't matter: standardizing healthcare-associated infection rates by bed days or device days. | LitMetric

Objective: To examine the impact on infection rates and hospital rank for catheter-associated urinary tract infection (CAUTI), central line-associated bloodstream infection (CLABSI), and ventilator-associated pneumonia (VAP) using device days and bed days as the denominator

Design: Retrospective survey from October 2010 to July 2013 SETTING: Veterans Health Administration medical centers providing acute medical and surgical care

Patients: Patients admitted to 120 Veterans Health Administration medical centers reporting healthcare-associated infections

Methods: We examined the importance of using device days and bed days as the denominator between infection rates and hospital rank for CAUTI, CLABSI, and VAP for each medical center. The relationship between device days and bed days as the denominator was assessed using a Pearson correlation, and changes in infection rates and device utilization were evaluated by an analysis of variance.

Results: A total of 7.9 million bed days were included. From 2011 to 2013, CAUTI decreased whether measured by device days (2.32 to 1.64, P=.001) or bed days (4.21 to 3.02, P=.006). CLABSI decreased when measured by bed days (1.67 to 1.19, P=.04). VAP rates and device utilization ratios for CAUTI, CLABSI, and VAP were not statistically different across time. Infection rates calculated with device days were strongly correlated with infection rates calculated with bed days (r=0.79-0.94, P<.001). Hospital relative performance measured by ordered rank was also strongly correlated for both denominators (r=0.82-0.96, P<.001).

Conclusions: These findings suggest that device days and bed days are equally effective adjustment metrics for comparing healthcare-associated infection rates between hospitals in the setting of stable device utilization.

Download full-text PDF

Source
http://dx.doi.org/10.1017/ice.2015.42DOI Listing

Publication Analysis

Top Keywords

bed days
32
infection rates
24
device days
24
days
14
days bed
12
infection
8
bed
8
device
8
rates hospital
8
hospital rank
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!