There is ongoing debate regarding the precise mechanisms underlying atrial fibrillation (AF). An improved understanding of these mechanisms is urgently needed to improve interventional strategies to suppress and eliminate AF, since the success of current strategies is suboptimal. At present, guidelines for AF ablation focus on pulmonary vein (PV) isolation for the prevention of arrhythmia. Additional targets are presently unclear, and include additional linear ablation and electrogram-guided substrate modification, without clear mechanistic relevance. PV and non-PV triggers are likely central in the first few seconds of AF initiation. Rapid activation from such triggers interacts with transitional mechanisms including conduction velocity slowing, action potential duration (APD) alternans, and steep APD restitution to cause conduction block and initiate functional reentry. However, complete suppression of potential triggers has proven elusive, and the intra-procedural mapping and targeting of transitional mechanisms has not been reported. A growing body of research implicates electrical rotors and focal sources as central mechanisms for the maintenance of AF. In several recent series, they were observed in nearly all patients with sustained arrhythmia. Ablation of rotor and focal source sites, prior to pulmonary vein isolation, substantially modulated atrial fibrillation in a high proportion of patients, and improved ablation outcomes versus pulmonary vein isolation alone. These results have subsequently been confirmed in multicenter series, and the improved outcomes have been found to persist to a mean follow-up of 3 years. Recently, rotors have been observed by multiple groups using diverse technologies. These findings represent a paradigm shift in AF, focusing on sustaining mechanisms, as is currently done with other arrhythmias such as atrioventricular node reentrant tachycardia. Studies are currently underway to assess the optimal strategy for the application of rotor-based ablation in AF management, including clinical trials on the relative efficacy of rotor-only ablation versus PVI-only ablation, which will inform future practice guidelines.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4800994 | PMC |
http://dx.doi.org/10.1007/s11936-015-0371-4 | DOI Listing |
Circ Arrhythm Electrophysiol
January 2025
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Y., G.N.K., N.O., T.K., L.N., D.L.P., K.C.S.).
Background: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.
View Article and Find Full Text PDFInt J Cardiol Heart Vasc
February 2025
Dept. of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands.
Background: Areas of conduction disorders play an important role in both initiation and perpetuation of AF and can be recognized by specific changes in unipolar potential morphology. For example, EGM fractionation may be caused by asynchronous activation of adjacent cardiomyocytes because of structural barriers such as fibrotic strands. However, it is unknown whether there are sex differences in unipolar potential morphology.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Department of Cardiology, School of Medicine, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.
Pulmonary vein isolation (PVI) with cryoballoon (CB) ablation technology is widely used to treat drug-resistant atrial fibrillation (AF). During CB ablation, there is a possibility of forming an ice cap of contrast-color on top of the balloon. If automatic balloon deflate occurs before the ice cap dissolves, embolization to the systemic circulation is possible.
View Article and Find Full Text PDFJACC Clin Electrophysiol
January 2025
Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas, USA; Interventional Electrophysiology, Scripps Clinic, San Diego, California, USA; Metro Health Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA; Department of Biomedicine and Prevention, Division of Cardiology, University of Tor Vergata, Rome, Italy. Electronic address:
Background: Earlier studies have documented the risk for sinoatrial node injury and phrenic nerve paralysis as complications following radiofrequency catheter ablation for electrical isolation of the superior vena cava (SVCI).
Objectives: The aim of this study was to assess the safety and feasibility of SVCI in patients with atrial fibrillation undergoing pulsed field ablation (PFA) METHODS: Six hundred sixteen consecutive patients undergoing PFA for pulmonary vein isolation plus SVCI were included in this multicenter analysis. Superior vena cava (SVC) ablation was performed under the continuous guidance of intracardiac echocardiography.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!