Objective: Osteopontin (OPN) is upregulated in adipose tissue (AT) in obesity and contributes to subclinical inflammation, adipocyte dysfunction, and insulin resistance. OPN effects can be increased by cleavage by matrix metalloproteinases (MMP). This study aimed at investigating the presence of OPN cleavage products in human AT in obesity and their impact on adipocyte function and immunological blockade of these effects.
Methods: AT of severely obese and control donors was investigated for OPN and MMP expression and the presence of OPN cleavage fragments. Primary adipocytes were isolated from human donors for in vitro investigation of cleaved OPN effects.
Results: OPN and MMP-9 expression was highly correlated in AT from obese donors, and increased levels of cleaved OPN were detected in AT from obese individuals. The in vitro effect of OPN on adipocyte inflammation and insulin resistance was enhanced by protease cleavage, which could finally be blocked with a monoclonal antibody directed against the MMP cleavage site of OPN.
Conclusions: These findings show that MMP cleavage of OPN in AT occurs in obesity, thereby enhancing OPN's inflammatory and pro-diabetic activity on adipocytes. Specifically targeting MMP-cleaved OPN opens avenues for prevention and treatment of obesity-induced type 2 diabetes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/oby.21024 | DOI Listing |
Clin Mol Hepatol
January 2025
Department of Biochemistry, College of Natural Sciences, Kangwon National University, 24341 Chuncheon, Republic of Korea.
J Dent Sci
December 2024
Division for Globalization Initiative, Liaison Center for Innovative Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan.
Background/purpose: Titanium dioxide nanotube (TNT) structures have been shown to enhance the early osseointegration of dental implants. Nevertheless, the optimal nanotube diameter for promoting osteogenesis remains unclear due to variations in cell types and manufacture of nanotubes. This study aimed to evaluate the differences in MC3T3-E1 and Saos-2 cells behavior on nanotubes of varying diameters.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Minneapolis Heart Institute and Minneapolis Heart Institute Foundation, Abbott Northwestern Hospital, Minneapolis, Minnesota, USA.
Introduction: The super high-pressure NC balloon (OPN NC; SIS Medical AG, Winterthur, Switzerland) is increasingly used in percutaneous coronary intervention (PCI). We performed a systematic review and meta-analysis of its efficacy and safety.
Methods: A systematic review was conducted using PubMed and the Cochrane Library to identify studies using the OPN NC balloon in PCI.
Zhongguo Zhong Yao Za Zhi
December 2024
State Key Laboratory of Traditional Chinese Medicine Syndrome, the First Affiliated Hospital of Guangzhou University of Chinese Medicine Guangzhou 510407, China Geriatrics Department, the First Affiliated Hospital of Guangzhou University of Chinese Medicine Guangzhou 510407, China Lingnan Medical Research Center, Guangzhou University of Chinese Medicine Guangzhou 510405, China Guangdong Clinical Research Institute of Chinese Medicine Guangzhou 510407, China.
This study aimed to investigate the ameliorative effect of Xinyang Tablets on myocardial fibrosis in uremic cardiomyopathy(UCM) using single-cell sequencing technology. UCM mouse models were established by 5/6 nephrectomy(NPM) and randomly divided into the model group, Xinyang Tablets group, and sham-operated(sham) group as the control. The Xinyang Tablets group received postoperative interventions of Xinyang Tablets(0.
View Article and Find Full Text PDFJ Adv Prosthodont
December 2024
Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
Purpose: This pilot study investigated the effect of surface roughness on osseointegration by comparing two types of commercial SLA-treated dental implants with different surface roughness levels: moderately rough (S = 1 - 2 µm) and rough surfaces (S > 2 µm).
Materials And Methods: Two implant groups were studied: TS (rough surface) and ADD (moderately rough surface) groups. Surface characteristics were analyzed using optical profilometry and SEM.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!