Accurate separation of air and bone is critical for creating synthetic CT from MRI to support Radiation Oncology workflow. This study compares two different ultrashort echo-time sequences in the separation of air from bone, and evaluates post-processing methods that correct intensity nonuniformity of images and account for intensity gradients at tissue boundaries to improve this discriminatory power. CT and MRI scans were acquired on 12 patients under an institution review board-approved prospective protocol. The two MRI sequences tested were ultra-short TE imaging using 3D radial acquisition (UTE), and using pointwise encoding time reduction with radial acquisition (PETRA). Gradient nonlinearity correction was applied to both MR image volumes after acquisition. MRI intensity nonuniformity was corrected by vendor-provided normalization methods, and then further corrected using the N4itk algorithm. To overcome the intensity-gradient at air-tissue boundaries, spatial dilations, from 0 to 4 mm, were applied to threshold-defined air regions from MR images. Receiver operating characteristic (ROC) analyses, by comparing predicted (defined by MR images) versus 'true' regions of air and bone (defined by CT images), were performed with and without residual bias field correction and local spatial expansion. The post-processing corrections increased the areas under the ROC curves (AUC) from 0.944 ± 0.012 to 0.976 ± 0.003 for UTE images, and from 0.850 ± 0.022 to 0.887 ± 0.012 for PETRA images, compared to without corrections. When expanding the threshold-defined air volumes, as expected, sensitivity of air identification decreased with an increase in specificity of bone discrimination, but in a non-linear fashion. A 1 mm air mask expansion yielded AUC increases of 1 and 4% for UTE and PETRA images, respectively. UTE images had significantly greater discriminatory power in separating air from bone than PETRA images. Post-processing strategies improved the discriminatory power of air from bone for both UTE and PETRA images, and reduced the difference between the two imaging sequences. Both post-processed UTE and PETRA images demonstrated sufficient power to discriminate air from bone to support synthetic CT generation from MRI data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4405190PMC
http://dx.doi.org/10.1088/0031-9155/60/7/2869DOI Listing

Publication Analysis

Top Keywords

air bone
24
petra images
20
images
12
ute images
12
discriminatory power
12
ute petra
12
air
10
separation air
8
intensity nonuniformity
8
radial acquisition
8

Similar Publications

Aims And Objectives: This study aimed to investigate the presence, type, and severity of hearing losses in individuals with Duane Retraction Syndrome (DRS), and to ascertain if there are anomalies in the auditory pathways at the brainstem level in DRS, believed to arise from aberrant interaction between cranial nerves and brainstem nuclei.

Study Design: Cross-sectional observational study.

Setting: Tertiary referral centre.

View Article and Find Full Text PDF

Objective: This study aimed to assess the functional and clinical outcomes of endoscopic Type 1 tympanoplasty in patients with chronic otitis media and tympanic membrane perforations, focusing on hearing improvement and graft success rates.

Methods: This retrospective study included 46 patients with dry tympanic membrane perforations who underwent endoscopic Type 1 tympanoplasty. Audiometric data, including pure tone averages (PTA) and air-bone gap (ABG) measurements at four frequencies (500, 1000, 2000, and 4000 Hz), were collected preoperatively and postoperatively.

View Article and Find Full Text PDF

Background: This study aimed to describe the arthroscopic superlateral capsule pathway technique for spotting femoral fixation device deployment, and to compare the results with normal procedure.

Methods: A total of 69 patients underwent ACLR (Anterior Cruciate Ligament Reconstruction) with or without the SCP (superolateral capsule pathway) during procedure were retrospectively selected and evaluated. A total of 36 patients underwent SCP and 33 patients underwent ACLR without SCP.

View Article and Find Full Text PDF

Background: The body composition of National Collegiate Athletic Association (NCAA) athletes is well documented but no such data exist for university club sports athletes. Additionally, the majority of norms for NCAA athletes were created from individual methods requiring assumptions.

Objective: This study used a four-component (4C) model to measure the body composition of university club sports athletes.

View Article and Find Full Text PDF

Otosclerosis is a well-known disease which mainly affects middle-aged female patients, causing conductive or mixed hearing loss. Diagnosis is essentially made through a complete audiometric battery testing, while treatment substantially relies on stapes surgery. In this study, we analyzed audiometric and Quality-of-Life data from 33 patients in order to refine the surgical indications (unilateral versus bilateral stapes surgery) and assess the best technique (stapedotomy versus partial stapedectomy) and timing of treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!