Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The purpose of this study was to assess predictive value of a new submaximal rowing test (SmRT) on 2,000-m ergometer rowing time-trial performance in competitive rowers. In addition, the reliability of the SmRT was investigated. Twenty-four competitive male rowers participated in this study. After determining individual HRmax, all rowers performed an SmRT followed by a 2,000-m rowing ergometer time trial. In addition, the SmRT was performed 4 times (2 days in between) to determine the reliability. The SmRT consists of two 6-minute stages of rowing at 70 and 80% HRmax, followed by a 3-minute stage at 90% HRmax. Power was captured during the 3 stages, and 60 seconds of heart rate recovery (HRR60s) was measured directly after the third stage. Results showed that predictive value of power during the SmRT on 2,000-m rowing time also increased with stages. CVTEE% is 2.4, 1.9, and 1.3%. Pearson correlations (95% confidence interval [95% CI]) were -0.73 (-0.88 to -0.45), -0.80 (-0.94 to -0.67), and -0.93 (-0.97 to -0.84). 2,000-m rowing time and HRR60s showed no relationship. Reliability of power during the SmRT improved with the increasing intensity of the stages. The coefficient of variation (CVTEM%) was 9.2, 5.6, and 0.4%. Intraclass correlation coefficients (ICC) and 95% CI were 0.91 (0.78-0.97), 0.92 (0.81-0.97), and 0.99 (0.97-1.00). The CVTEM% and ICC of HRR60s were 8.1% and 0.93 (0.82-0.98). In conclusion, the data of this study shows that the SmRT is a reliable test that it is able to accurately predict 2,000-m rowing time on an ergometer. The SmRT is a practical and valuable submaximal test for rowers, which can potentially assist with monitoring, fine-tuning and optimizing training prescription in rowers.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/JSC.0000000000000902 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!