Purpose: We compared the fixation stability measurements obtained with two microperimeters, the Micro Perimeter 1 (MP-1) and the Spectral OCT/SLO (OCT/SLO), in subjects with and without maculopathies.
Methods: A total of 41 eyes with no known ocular diseases and 45 eyes with maculopathies were enrolled in the study. Both eyes of each participant had a 20-second fixation test using the MP-1 and OCT/SLO. The bivariate contour ellipse area (BCEA) was used for fixation stability evaluation.
Results: In the normal group, BCEA was 2.93 ± 0.32 log minarc on OCT/SLO and 2.89 ± 0.30 log minarc on MP-1. In the maculopathy group, BCEA was 3.05 ± 0.41 log minarc on OCT/SLO and 3.15 ± 0.46 log minarc on MP-1. There was no statistically significant difference between the BCEA measured by OCT/SLO and by MP-1 in both groups. A moderate correlation was found between the two devices ( = 0.45, < 0.001). The sample size during the fixation test was 535.5 ± 14.6 pairs of coordinates in the normal group and 530.7 ± 14.9 pairs in the maculopathy group with MP-1, while it was 72.3 ± 6.9 and 59.9 ± 10.1, respectively, with OCT/SLO. This was due to different tracking frequencies between the two microperimeters.
Conclusion: Fixation stability assessment yields similar results using the OCT/SLO and MP-1. A major difference in sampling rate between the two microperimeters does not significantly affect BCEA measurements.
Translational Relevance: Fixation stability assessments are comparable and interchangeable between the OCT/SLO and the MP-1.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4356036 | PMC |
http://dx.doi.org/10.1167/tvst.4.2.3 | DOI Listing |
J Orthop
August 2025
University of Alabama at Birmingham, Department of Orthopaedic Surgery, Birmingham, AL, USA.
Purpose: This study aims to compare the biomechanical performance of elastic and static suture-based cerclage systems to traditional screw constructs in the setting of modeled glenoid bony augmentation.
Methods: Biomechanical testing was conducted on polyurethane cellular foam blocks modeling a 20 % glenoid defect repaired with a coracoid graft. Constructs consisted of an elastic suture-based cerclage, static suture-based cerclage, and a two-screw construct.
Surg Pract Sci
September 2022
University of California, Division of Trauma, Burns & Surgical Critical Care, 333 City Blvd West, Suite 1600, Irvine, Orange, CA, 92868, United States.
Responsible for approximately 35% of all trauma-related deaths in the United States, thoracic trauma is one of the leading causes of death among trauma patients. Furthermore, traumatic rib fractures represent the most frequently encountered injury following thoracic trauma with mortality rates ranging from 8% among the elderly to 13% for patients with a flail chest. This manuscript reviews the history of SSRF as well as the contributions of the pioneering surgeons who championed this treatment.
View Article and Find Full Text PDFSurg Pract Sci
March 2025
Arizona Center of Hand to Shoulder Surgery, Phoenix, AZ, United States.
Introduction: Time spent in the operating room (OR) has ramifications that impact patient outcomes and the economics of patients, physicians, surgery centers, and insurance industry. For that reason, there is an incentive to seek approaches that allow shorter times to be spent in the OR. To what extent varying routine techniques impact on operating times has not been extensively studied in metacarpal fixation literature, specifically investigating retrograde threaded intramedullary nail fixations (RTNF) and comparing it to open plating fixations (OPF).
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2025
Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China.
Background: Currently, some novel rods with lower elastic modulus have the potential as alternatives to traditional titanium alloy rods in lumbar fusion. However, how the elastic modulus of the rod (rod-E) influences the biomechanical performance of lumbar interbody fusion remains unclear. This study aimed to explore the quantitative relationships between rod-E and the biomechanical performance of transforaminal lumbar interbody fusion (TLIF).
View Article and Find Full Text PDFSci Rep
January 2025
U1008 - Advanced Drug Delivery Systems and Biomaterials, Univ. Lille, INSERM, CHU Lille, Lille, F-59000, France.
This study aimed to compare the failure rates of two different sizes of plates and screws to stabilize critical-sized (7 mm) femoral defects in male Sprague‒Dawley rats (aged 10 weeks). Femoral defects were stabilized with either a 4-hole plate (length 29 mm, thickness 1 mm, 10 rats, Group 1) and 4 cortical screws (diameter 2 mm) or with a 6-hole plate (length 30 mm, thickness 0.6 mm, 9 rats, Group 2) and 4 cortical screws (diameter 1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!