Objectives: Indocyanine green (ICG) with near-infrared (NIR) fluorescence imaging is a new tracer modality used for lymphatic mapping. We report our initial experience with ICG for SLN mapping in cervical and endometrial cancer using a new endoscopic fluorescence imaging system.

Methods: We reviewed all patients who underwent primary surgery for early-stage endometrial and cervical carcinoma with SLN mapping using fluorescence imaging followed by pelvic lymphadenectomy from February to July 2014. Intracervical injection of ICG at 3 and 9 o'clock was performed in all cases. SLNs were ultrastaged on final pathology. Sensitivity and specificity values were calculated.

Results: A total of 50 patients were included in the study (42 endometrial and 8 cervical cancers). The median age was 62 (24-88) and median BMI 29 (19-56). The median SLN count was 3.1 (0-7) and median lymph node count was 15 (2-37). The overall and bilateral detection rate was 96% (48/50) and 88% (44/50). Positive SLNs were identified in 22% of patients (11/50), including 8 isolated tumor cells (ITC), 2 micrometastasis and 1 macrometastasis. There was one side-specific false negative case. Sensitivity, specificity and NPV were 93.3%, 100% and 98.7% respectively per side. Paraaortic node dissection was performed in 22% of cases. Two had paraaortic node metastasis both in patients with positive pelvic SLN. There were no allergic reactions to the ICG.

Conclusions: Based on our pilot experience, NIR fluorescence imaging with ICG is an excellent and safe tracer modality for SLN mapping with a very high overall (96%) and bilateral (88%) detection rate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ygyno.2015.03.004DOI Listing

Publication Analysis

Top Keywords

fluorescence imaging
20
sln mapping
12
indocyanine green
8
endometrial cancer
8
nir fluorescence
8
tracer modality
8
endometrial cervical
8
sensitivity specificity
8
detection rate
8
paraaortic node
8

Similar Publications

Optical techniques, such as functional near-infrared spectroscopy (fNIRS), contain high potential for the development of non-invasive wearable systems for evaluating cerebral vascular condition in aging, due to their portability and ability to monitor real-time changes in cerebral hemodynamics. In this study, thirty-six healthy adults were measured by single channel fNIRS to explore differences between two age groups using machine learning (ML). The subjects, measured during functional magnetic resonance imaging (fMRI) at Oulu University Hospital, were divided into young (age ≤ 32) and elderly (age ≥ 57) groups.

View Article and Find Full Text PDF

Assessment of corneal vessels activity through the 'Barcode sign' of corneal OCT.

Eye (Lond)

January 2025

Division of Clinical Neuroscience, Department of Ophthalmology, University of Nottingham, Nottingham, UK.

Background/objectives: Anterior segment optical Coherence Tomography (AS-OCT) is used extensively in imaging the cornea in health and disease. Our objective was to analyse and monitor corneal vascularisation (CVas) through the corresponding back-shadows visible on AS-OCT.

Subjects/methods: AS-OCT scans were obtained from 26 consecutive patients (eyes) with CVas of different aetiologies.

View Article and Find Full Text PDF

Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.

View Article and Find Full Text PDF

High-resolution fluorescence imaging of ultracold atoms and molecules is paramount to performing quantum simulation and computation in optical lattices and tweezers. Imaging durations in these experiments typically range from a millisecond to a second, significantly limiting the cycle time. In this work, we present fast, 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!