Mutagenic hazards related to occupational exposure to nitrous oxide and enflurane was studied in the personnel of five operating rooms using a coupled environmental and biological monitoring approach. The environmental monitoring revealed air concentrations of the two anesthetics exceedings the TLVs by 10-15-fold. These values were correlated individually with the concentrations of the two anesthetics in the expired air of the exposed subjects. The biological monitoring was carried out by determining two parameters associated with mutagen exposure (urinary mutagenicity and thioethers) and a parameter associated with the enzymatic induction (D-glucaric acid) in the urine of exposed and unexposed subjects (N = 64 and N = 37, respectively). The results showed no difference in the two groups for urine mutagenicity and D-glucaric acid, but urine thioethers were significantly increased among highly exposed subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1002/tcm.1770090604DOI Listing

Publication Analysis

Top Keywords

d-glucaric acid
12
acid urine
12
biological monitoring
8
concentrations anesthetics
8
exposed subjects
8
thioethers mutagens
4
mutagens d-glucaric
4
urine
4
urine operating
4
operating room
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!