A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Benefits for Adults with Transfemoral Amputations and Peripheral Artery Disease Using Microprocessor Compared with Nonmicroprocessor Prosthetic Knees. | LitMetric

Objective: Approximately 50% of people with leg amputation fall annually. Evidence suggests that microprocessor knees (MK) may decrease falls and improve prosthetic function in people with traumatic amputations. This study explored whether adults with transfemoral amputations and peripheral artery disease would have reduced falls and improved balance confidence, balance, and walking ability when using prostheses with MK compared with non-MK.

Design: This was a prospective cohort study.

Results: Eight subjects averaged 60.8 ± 11.3 yrs or age and 9.5 ± 16.1 yrs since first amputation. Four were K1-K2-level and four were K3-level functional walkers; only Houghton prosthetic use score was different between K1-K2 and K3 walkers (P = 0.03). After 48.3 ± 38.1 wks of acclimation using MK, subjects demonstrated improvements in fear of falling, balance confidence, Timed Up-and-Go time, and rate of falls (P < 0.05). The improvements in fear of falling, balance confidence, and rate of falls had large effect sizes (d > 0.80). Average decreased Timed Up-and-Go time (12.3 secs) had a medium effect size (d = 0.34). Decreases in the number of falls correlated with faster Timed Up-and-Go speed (ρ = -0.76) and greater balance confidence (ρ = 0.83).

Conclusions: People with peripheral artery disease and transfemoral amputations had fewer falls and improved balance confidence and walking performance when using prostheses with MK.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PHM.0000000000000265DOI Listing

Publication Analysis

Top Keywords

balance confidence
20
transfemoral amputations
12
peripheral artery
12
artery disease
12
timed up-and-go
12
adults transfemoral
8
amputations peripheral
8
falls improved
8
improved balance
8
improvements fear
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!