Early clinical and radiographical results of keel-less and shallow keel cervical disc replacement.

Asian J Neurosurg

Department of Neurosurgery, National Neuroscience Institute, 11 Jalan Tan Tock Seng, 308433 Singapore ; Department of Neurosurgery, Singapore General Hospital, Academia, Level 5, 169865 Singapore ; Spine Neuro Specialist Centre, Gleneagles Medical Centre, 258499 Singapore.

Published: March 2015

Background: Cervical disc replacements has been shown to be as effective as fusions in the treatment of radiculopathy or myelopathy due to disc prolapse. Newer implants were designed to reduce the difficulty of end-plate preparation. Since 2010, the authors have started using Discocerv (Alphatec Spine, Carlsbad, USA) a keel-less implant and Activ-C (B. Braun, Sheffield, UK), a shallow keel implant.

Aim: The aim of this study was to compare the duration of surgery between cervical disc replacement and anterior cervical discectomy and fusion, and also to evaluate the functional outcome, complications, and radiographic outcome of cervical disc replacement.

Results: Fifty patients were included (20 disc replacement and 30 fusion). This was a single surgeon retrospective study, with all surgery performed by the senior author (RT). The mean operation duration for single-level disc replacement was 2.6 h, and for single-level fusion was 2.4 h (P = 0.4684). For 2-levels surgery, the result was 3.5 h for 2-level hybrid surgery (one level disc replacement and one level fusion) and 3.4 h for fusion (P = 0.4489). Disc replacement resulted in preservation of an average of 67% of the angle of motion at the sagittal plane (FFflexion-extension). The average range of motion after disc replacement was 6.1°. The median clinical follow-up duration was 2 years (average 1.8 years). There was no incidence of major complications or significant neurovascular injury in this series of patients. A significant improvement in short form-36 scores was seen as early as 3 months postoperative (from 58 preoperative to 92 at 3 months). The improvement was sustained up to the fourth year of follow-up.

Conclusion: Cervical arthroplasty with keel-less and shallow keel implants are safe and relatively easy to perform. The surgical time for disc replacement is not significantly longer than standard fusion surgery. There is reasonably good preservation of motion. The short-term functional improvement is good, and we await further long-term outcome results. The authors felt that cervical disc replacement will have an important role in the treatment of cervical degenerative disc disease in the future.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4352635PMC
http://dx.doi.org/10.4103/1793-5482.151501DOI Listing

Publication Analysis

Top Keywords

disc replacement
36
cervical disc
20
disc
13
shallow keel
12
replacement
9
keel-less shallow
8
cervical
8
fusion
6
surgery
5
early clinical
4

Similar Publications

Background: Secondary mitral regurgitation (SMR) is a condition affecting the left ventricle (LV) rather than the mitral valve (MV). If the MV remains structurally unchanged, enlargement of the LV or impairment of the papillary muscles can occur. Several mechanical interventions are available to dictate the resolution of MR.

View Article and Find Full Text PDF

Secondary mitral regurgitation (SMR) is characterized by a pathological process impacting the left ventricle (LV) as opposed to the mitral valve (MV). In the absence of structural alterations to the MV, the expansion of the LV or impairment of the papillary muscles (PMs) may ensue. A number of technical procedures are accessible for the purpose of determining the optimal resolution for MR.

View Article and Find Full Text PDF

Study Design: Matched case-control study.

Purpose: To evaluate the midterm outcomes of unilateral pedicle screw fixation (UPSF) versus bilateral pedicle screw fixation (BPSF) in transforaminal lumbar interbody fusion (TLIF) procedure, ascertain efficacy of UPSF in adequately decompressing contralateral foramen+spinal canal and reducing rate of adjacent segment degeneration (ASD) at 4-8-year follow-up (FU).

Overview Of Literature: Previous meta-analyses found no significant differences between UPSF and BPSF regarding fusion rates, clinical and radiological outcomes; however, few studies have reported higher rates of cage migration/subsidence and pseudoarthrosis in the UPSF.

View Article and Find Full Text PDF

Study Design: A retrospective comparative study.

Purpose: To validate the hypothesis that a combination of multilevel Ponte osteotomy (PO) with intraoperative traction (IOT) results in a better correction than IOT alone in high-magnitude curves in adolescent idiopathic scoliosis (AIS) and does not possess an attributable risk of neurological injury.

Overview Of Literature: On a comprehensive review of the literature, the choice of technique adopted for curves between 65° and 100° remains controversial with no major consensus favoring one technique over the other.

View Article and Find Full Text PDF

Device profile of the Mobi-C artificial cervical disc: an overview of its safety and efficacy.

Expert Rev Med Devices

January 2025

Department of Orthopaedic Surgery, UC Davis Health, Sacramento, California, USA.

Article Synopsis
  • The Mobi-C Cervical Disc Replacement is FDA-approved for treating multiple levels of the cervical spine and is shown to be effective compared to traditional fusion surgery based on clinical trial data.
  • The article reviews the history, biomechanics, clinical results, long-term outcomes, and cost-effectiveness of Mobi-C, indicating it is a strong alternative to fusion.
  • Expert opinion highlights Mobi-C's proven track record, suggesting it preserves motion, provides positive clinical outcomes, and ensures patient safety, making it a favorable option for appropriate candidates.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!