Background And Aim: When a mandibulectomy causes discontinuity, the patient will need a rehabilitative prosthesis to achieve a proper occlusal relationship.

Technique: This article describes step-by-step guidelines for measuring the patient-specific mandibular guide flange angulation. In the presented technique, the flange angulation is determined by dividing the horizontal overlap of the maxillary posterior teeth plus the maxillary buccal clasp thickness by the vertical distance of the mandibular continuous clasp up to the maxillary buccal clasp.

Discussion: The mandibular guiding flange prosthesis must achieve an angulation that is appropriate for the particular circumstances of each patient to minimize the complications with mandibular deviation.

Clinical Relevance: The introduced method for measuring the patient-specific mandibular guide flange angulation can help prosthodontists to prepare the mandibular guiding flange prosthesis with higher accuracy and predictability.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0309364615574160DOI Listing

Publication Analysis

Top Keywords

flange angulation
16
mandibular guide
12
guide flange
12
prosthesis achieve
8
measuring patient-specific
8
patient-specific mandibular
8
maxillary buccal
8
mandibular guiding
8
guiding flange
8
flange prosthesis
8

Similar Publications

Potential role of the light-adjustable lens in flanged intrascleral haptic fixation.

J Cataract Refract Surg

July 2024

From the Department of Ophthalmology, Willis-Knighton Medical Center, Shreveport, Louisiana (LoBue, Martin, Shelby, Coleman); Department of Ophthalmology, SUNY Downstate Medical Center, Brooklyn, New York (Saba); St. Georges University School of Medicine, Grenada, West Indies (Catapano).

Article Synopsis
  • The study compares the maximum tensile strength of different 3-piece intraocular lenses (IOLs) used for flanged intrascleral haptic fixation (FISHF) at the Willis-Knight Eye Institute in Louisiana.
  • Results showed that the CT Lucia lens had the highest strength (1.53 N), outperforming other lenses like the MA60AC, AR40E, and LAL, with significant differences noted (P < .001).
  • The findings suggest that while the strength and angulation of lenses like the CT Lucia may support safe use in FISHF by skilled surgeons, more research is needed to ensure stability under physiological conditions or with light treatments.
View Article and Find Full Text PDF

Objective: To report a bone hook reduction technique combined with lateral parapatellar arthrotomy for periprosthetic distal femoral fractures following total knee arthroplasty (TKA).

Methods: From April 2012 to June 2018, a total of 31 knees who underwent this technique for the treatment of periprosthetic distal femoral fractures following TKA were retrospectively reviewed. Through a lateral parapatellar arthrotomy, the vastus lateralis fascia was dissected from the muscle belly to allow anteromedial mobilization of the muscles.

View Article and Find Full Text PDF

Pygidiapion De Sousa amp; Mermudes, a new genus of Apioninae (Brentidae: Apioninae: Apionini) associated with Fabaceae from Brazil, with the description of a new species and transfer of Apion zikani Heller, 1922.

Zootaxa

March 2021

Universidade Federal de Rondonópolis, Instituto de Ciências Exatas e Naturais, Rodovia Rondonópolis-Guiratinga MT 270, Km 6, s/n. Rondonópolis, Mato Grosso, Brazil. 78735-901..

The genus Pygidiapion De Sousa Mermudes gen. n., described and illustrated here, includes two species from Brazil: the type-species Pygidiapion zeppelinii De Sousa Mermudes sp.

View Article and Find Full Text PDF

Background: Fracture of femoral component in total knee arthroplasty (TKA) has become a rare complication with improvements in metal alloy manufacturing technology.

Methodology: We report two cases of fracture of femoral components 9 and 10 years after primary TKA. The Buechel-Pappas (BP) knee system used in our two cases were designed by the same team who designed the LCS TKA implants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!