Purpose: Aortic vessel wall imaging requires large coverage and a high spatial resolution, which makes it prohibitively time-consuming for clinical use. This work explores the feasibility of imaging the descending aorta in acceptable scan time, using two-dimensional (2D) spatially selective excitation and a new way of inversion recovery for black blood imaging.

Methods: The excitation pattern and field of view in a 3D gradient echo sequence are reduced in two dimensions, following the aorta's anisotropic geometry. Black blood contrast is obtained by partially inverting the blood's magnetization in the heart at the start of the cardiac cycle. Imaging is delayed until the inverted blood has filled the desired part of the aorta. The flip angle and delay are determined such that the blood signal is nulled upon arrival in the aorta.

Results: Experiments on eight volunteers showed that the descending aortic vessel wall could be imaged over more than 15 cm at a maximal resolution of 1.5 × 1.5 × 1.5 mm(3) in less than 5 min minimal scan time.

Conclusion: This feasibility study demonstrates that time-efficient isotropic imaging of the descending aorta is possible by using 2D spatially selective excitation for motion artifact reduction and a new way of inversion recovery for black blood imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.25599DOI Listing

Publication Analysis

Top Keywords

black blood
16
aortic vessel
12
vessel wall
12
spatially selective
12
selective excitation
12
inversion recovery
12
recovery black
12
isotropic imaging
8
excitation inversion
8
blood imaging
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!