Background: One of the main goals of scoliosis surgery is to obtain a balanced fused spine. Although preoperative planning remains essential, intraoperative posteroanterior radiographs are the only available tool during the procedure to verify shoulder and coronal spinal balance and, if necessary, adjust the construct. The aim of this study was to quantify the direct influence of intraoperative radiographs on the surgical procedure itself during correction of adolescent idiopathic scoliosis.
Methods: Retrospective analysis of prospectively collected data on a monocentric cohort of adolescent idiopathic scoliosis patients undergoing corrective surgery. A total 148 consecutive patients operated in the same department following the same validated preoperative planning method were included in this prospective radiologic study. The mean follow-up averaged 33 months. Frontal Cobb angles, T1 tilt, shoulder tilt, iliolumbar angle, and frontal balance were measured and compared on intraoperative, early postoperative, and latest follow-up radiographs. Any intraoperative modification of the correction performed after analysis of the intraoperative radiograph were recorded.
Results: The analysis of all radiologic parameters was possible in 90.5% of the cases. In 9.5% of the cases, shoulders could not be properly distinguished. Significant modifications on the upper thoracic curve to correct T1 tilt or shoulder balance were performed in 29% of the patients, and changes at the distal levels were recorded in 19%, underlining planification imperfections. On postoperative standing radiographs, the average coronal parameters were neutral, without loss of correction at follow-up.
Conclusions: Intraoperative radiographs remain necessary to ensure compensation of the shortcomings of the modern preoperative planification method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BPO.0000000000000428 | DOI Listing |
JSES Rev Rep Tech
February 2025
Department of Orthopaedics, Krishna Institute of Medical Sciences, Secunderabad, Telanagana, India.
Hypothesis: Proximal humerus fractures present a treatment challenge due to varied fracture configurations and a lack of consensus on optimal management. Locking plate designs offer promising solutions, yet technical guidelines for successful outcomes remain elusive. Complications are common, with fixation-related failures often attributed to varus collapse.
View Article and Find Full Text PDFDislocation is the second most common indication for revision total hip arthroplasty (THA). In revision cases the dislocation rate can be as high as 5-30%. The aim of this study was to assess the outcome, specifically the dislocation rate in revision THA where a dual mobility cup was used.
View Article and Find Full Text PDFPurpose: Anterior tibial closing wedge osteotomy (ATCWO) has been shown to significantly reduce failure rates of revision anterior cruciate ligament (ACL) reconstructions in patients with a posterior tibial slope (PTS) ≥12°. Recent findings suggest a slight but significant reduction of the medial proximal tibial angle (MPTA) resulting in a varus knee where the sagittal osteotomy plane is based on a total of two guide wires defining the osteotomy wedge without respecting the frontal plane. We hypothesize that the placement of a total of four guide wires intraoperatively can reduce the influence on the MPTA.
View Article and Find Full Text PDFAm J Sports Med
January 2025
Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA.
Background: Intraoperative hip capsule management is increasingly recognized as an important component of hip arthroscopy for the prevention of capsular-related instability. The periportal capsulotomy, relative to the interportal capsulotomy, has been proposed as a minimally invasive technique for decreasing postarthroscopy hip instability; however, the biomechanical effects of this technique are not well established.
Purpose/hypothesis: This study aimed to provide a biomechanical characterization of interportal and periportal capsulotomies, helping inform surgeon choice of capsulotomy type and repair, potentially guiding clinical practice in hip arthroscopy.
J Clin Med
January 2025
Servicio de Cirugía Ortopédica y Traumatología, Hospital La Paz-IdiPaz, 28046 Madrid, Spain.
: Surgical accuracy in total knee replacement (TKR) may vary with the surgeon, the patient preoperative deformity, and the guiding system to perform the procedure. Navigation systems attempt to increase the intraoperative information the surgeon requires to make the appropriate decisions, sometimes associating cumbersome procedures and unclear effectiveness to place the implant more precisely than conventional instruments. : We conducted a retrospective case-control study with prospective data collection of radiographic measurements (alignment, joint line and patellar height) in a sample of 100 consecutive patients receiving TKR Optetrak Logic PS, either with standard surgical technique with Trulion Instrumentation ( = 59) or with the Guided Personalized Surgery (GPS) system ( = 41).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!