A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Update on cannulation techniques. | LitMetric

Update on cannulation techniques.

J Vasc Access

Division of Nephrology, Department of Medicine, University of Missouri, Columbia, MO - USA.

Published: December 2015

There are two methods of fistula cannulation for hemodialysis. The first, different site or rope-ladder cannulation method, established by originators of the arteriovenous fistula as a blood access for hemodialysis in 1966, relies on changing the puncture sites for each dialysis. The second, constant site or buttonhole method, developed several years later, recommends using the same puncture sites for consecutive dialyses. The first method is prevailing at present, but the second method is becoming more and more popular. The major advantage of this buttonhole method is lower cannulation pain, fewer fistula complications, with the exception of fistula infection, which is more common in some studies. This method is more difficult and requires experienced single cannulator to establish good puncture sites. Home hemodialysis patients using single cannulator, the patient or helper, have better results with this method. Busy dialysis centers with high rotation of cannulators do not have as good results and prefer the rope-ladder method.

Download full-text PDF

Source
http://dx.doi.org/10.5301/jva.5000349DOI Listing

Publication Analysis

Top Keywords

puncture sites
12
method
8
buttonhole method
8
single cannulator
8
update cannulation
4
cannulation techniques
4
techniques methods
4
fistula
4
methods fistula
4
fistula cannulation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!