Background: Skull base lesions are challenging to treat and may be managed using several approaches each with its own advantages and limitations. In selected cases, a modular, combined, multiportal approach could overcome the limits of a single approach and respond well to the needs of the patient.
Methods: We report a preclinical study on 5 cadaveric specimens and 4 preliminary clinical experiences with the combined multiportal transnasal transorbital endoscopic approach for the management of selected complex skull base pathologies. The technical feasibility and safety of this combined approach were evaluated in the preclinical study. The applicability in vivo of such an approach, together with early and late complications, specific morbidity, and hospitalization time were analyzed in the preliminary clinical experiences.
Results: The transnasal endoscopic extended approach combined with the transorbital endoscopic approach offered greater visualization and tissue handling than a single approach alone could. The multiportal combined transorbital transnasal endoscopic approach was used effectively in vivo to resect 1 case of malignant schwannoma arising from the second branch of the trigeminal nerve and 3 cases of spheno-orbital meningioma without significant complications and with minimal morbidity for the patients.
Conclusions: The multiportal combined transorbital transnasal endoscopic approach is a safe and effective procedure for management of selected complex skull base lesions that is able to capitalize on the advantages and overcome the limitations of each single approach. This combined approach offers a multiperspective view of the spaces and allows for a more synergized procedure, especially when dealing with multicompartmental lesions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.wneu.2015.02.034 | DOI Listing |
Oper Neurosurg (Hagerstown)
January 2025
Department of Neurological Surgery, Mayo Clinic, Phoenix, Arizona, USA.
Am J Gastroenterol
January 2025
Division of Gastroenterology, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand.
Background Aims: Non-invasive tests (NITs), e.g. Fibrosis-4 Index (FIB-4) and vibration-controlled elastography (VCTE), have been used to identify metabolic dysfunction-associated steatotic liver disease (MASLD) patients at high risks for hepatocellular carcinoma (HCC).
View Article and Find Full Text PDFObjective: The Laparoscopic Approach to Cervical Cancer trial demonstrated that minimally invasive radical hysterectomy was associated with worse disease-free survival and overall survival among women with early-stage cervical cancer. It is unknown whether this applies to patients with low-risk disease following simple hysterectomy.
Methods: Among patients who underwent simple hysterectomy in the Simple Hysterectomy And PElvic node assessment trial, univariate and multivariate Cox models were used to assess the association of minimally invasive versus open surgery with clinical outcomes, including pelvic and extra-pelvic recurrence-free survival, overall recurrence-free survival, and overall survival.
Clin Otolaryngol
January 2025
School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Introduction: The nasoseptal flap (NSF) has become a widely favoured choice for reconstructing skull base defects following the endoscopic endonasal approach (EEA). However, the exposed septal cartilage and bone at the donor site often require an extended duration for secondary healing. This study investigated whether the free middle turbinate (MT) mucosa grafting at the septal donor site could mitigate post-operative nasal morbidity.
View Article and Find Full Text PDFFlexible infrared image fiber bundles (FBs) are capable of delivering thermal images of areas that are difficult for ordinary thermal cameras to access while making the imaging systems compact and lightweight. Thus, FB-based thermal imaging systems show great potential in some important applications, such as infrared endoscopy, aircraft infrared warning, and satellite remote sensing. In most applications, FBs are required to have high overall transmittance (OT) and high spatial resolution (), but the fabrication of such high-performance FBs is still a challenge.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!