Ocular biocompatibility evaluation of hydroxyl-functionalized graphene.

Mater Sci Eng C Mater Biol Appl

Institute of Advanced Materials for Nano-Bio Applications, School of Ophthalmology & Optometry, Eye Hospital, Wenzhou Medical University, 270 Xueyuan Xi Road, Wenzhou, Zhejiang 325027, China; Center of Advanced Science and Engineering for Carbon (Case4Carbon), Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH 44106, United States. Electronic address:

Published: May 2015

We have presented our recent efforts on genotoxicity and intraocular biocompatibility of hydroxylated graphene (G-OH) prepared by ball milling. We have previously demonstrated that the as-synthesized G-OH could be considered as an excellent alternative for graphene oxide which had been applied widely. Following our last report on G-OH, we carried out detailed studies on genotoxicity and in vivo biocompatibility of G-OH in this work. Less than 5% enhanced caspase-3 level was observed for cells exposed to more than 50 μg/mL G-OH over 72 h, suggesting G-OH caused cell apoptosis was slight. The G-OH induced DNA damage was also found to be mild since expression of p53 and ROS regeneration level was quite low even at high concentration of G-OH over a long time. Cell viability was found to be higher than 90% with 50 μg/mL G-OH and 80% with 100 μg/mL G-OH using flow cytometry. Comet results suggested that less than 5% tail could be found with 100 μg/mL G-OH. TEM results confirmed that G-OH could penetrate into and out of the cytoplasm by means of endocytosis and exocytosis without causing damage on cell membranes. In vivo biocompatibility of G-OH was studied by intravitreal injection of G-OH into rabbits. The ocular fundus photography results showed that G-OH could be diffused in the vitreous body gradually without any damage caused. Injection of G-OH had caused few damages on eyesight related functions such as intraocular pressure, electroretinogram and histological structures of the retina.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.msec.2015.01.086DOI Listing

Publication Analysis

Top Keywords

g-oh
16
μg/ml g-oh
16
vivo biocompatibility
8
biocompatibility g-oh
8
g-oh caused
8
100 μg/ml
8
injection g-oh
8
ocular biocompatibility
4
biocompatibility evaluation
4
evaluation hydroxyl-functionalized
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!