Objective: To evaluate force decay between intermaxillary orthodontic elastics with and without latex in the oral medium at different time intervals.
Materials And Methods: Intermaxillary orthodontic elastics with and without latex [1/8″ (3.2mm), 1/4″ (6.35mm), and 5/16″ (7.94mm) in diameter] were evaluated 'clinically'. For this purpose, 26 patients served as hosts for the elastics during the evaluation period. Initially, 52 thermoplasticized plates 1mm thick were made according to the patients' mould. Then, the orthodontic accessories were bonded to the plates, which kept the elastics distended throughout the experimental period. The force released by the elastics at this distance was evaluated at 0, 12, and 24 hours. Statistical analyses were performed using the Friedman, Wilcoxon, and Mann-Whitney tests (significance set at 5 per cent).
Results: Elastics with and without latex presented with permanent deformation and increasing internal diameter throughout the entire period. Elastics with latex, 1/8″ (3.2mm) in diameter, sustained higher levels of force than those without latex. Elastics measuring 1/4″ (6.35mm) and 5/16″ (7.94mm) in diameter without latex sustained higher levels of force at 0 and 12 hours compared to those with latex. At the end of the experiment (24 hours), no significant difference was observed between the elastics (P > 0.05).
Limitations: This study only evaluated three time intervals: 0, 12, and 24 hours. If the behaviour was evaluated at different time intervals, different behaviours of these materials might be revealed.
Conclusion: Elastics with latex 1/8″ in diameter sustained a higher level of final force than the corresponding type without latex. The 1/4 and 5/16 elastics with and without latex were not different at the end of the evaluation period.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ejo/cjv005 | DOI Listing |
Physiol Meas
January 2025
Electronics, Universidad Favaloro, Solis 453, Buenos Aires, Buenos Aires, 1078, ARGENTINA.
Aortic dilatation is a severe pathology that increases the risk of rupture and its hemodynamics could be accurately assessed by using the 4D flow cardiovascular magnetic resonance (CMR) technique but flow assessment under complex flow patterns require validation. The aim of this work was to develop an in vitro system compatible with CMR to assess the accuracy of volume flow measurements in dilated aortas. Approach.
View Article and Find Full Text PDFMolecules
December 2024
Key Laboratory of Advanced Materials of Ministry of Education of China, Department of Chemical Engineering, Tsinghua University, Beijing 100084, China.
Waterborne polyurethane, with a mechanical strength comparable to solvent-based types, is eco-friendly and safe, using water as a dispersion medium. Polyacrylate excels in film formation and weather resistance but suffers from "hot stickiness and cold brittleness". Merging polyurethane and polyacrylate creates advanced hybrids, while organosilicon enhances properties but is restricted due to hydrolytic crosslinking.
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
Post-Graduation Program in Materials Sciences (PPGCM), Federal University of São Carlos (UFSCar), 18052-780, Brazil; Laboratory of Biomaterials, Faculty of Medical Sciences and Health (FCMS), Pontifical Catholic University of São Paulo (PUC-SP), 18030-070, Brazil; Mechanical Engineering Faculty (FEM), State University of Campinas (UNICAMP), 13083-970, Brazil; Post-Graduation Program of Biomaterials and Regenerative Medicine (PPGBMR), Surgery Department, (PUC-SP), 18030-070, Brazil.
Wound healing is a complex process involving a sequence of factors that can be disrupted, negatively impacting the quality of life for patients and overburdening healthcare systems. Advanced dressings obtained by electrospinning are highlighted by the optimization of this process, allowing air exchange and protection against microorganisms. Aiming to develop bioactive dressings, this study investigated the physicochemical, mechanical, microbiological, and in vitro biological properties of membranes containing 25 %, 50 %, 75 %, and 90 % copaiba oil (CO) co-electrospun with poly(L-co-D,L-lactic acid) (PLDLA) and natural rubber latex (NR).
View Article and Find Full Text PDFBiomacromolecules
January 2025
Department of Chemical Engineering, Smith Engineering, Queen's University, Kingston, Ontario K7L 3N6, Canada.
Latex-based nanocomposites containing carboxylated cellulose nanocrystals (cCNCs) were synthesized via in situ seeded semibatch emulsion polymerization. Inspired by nature's use of CNCs to enhance rigidity and mechanical strength in cellulosic materials, we explored similar principles to improve the properties of acrylate water-based coatings. The cCNCs, loaded at 0.
View Article and Find Full Text PDFPurpose: The purpose of this laboratory study was to evaluate common materials for isolation and neutralizing agents for hydrofluoric acid (HF). Additionally, surfaces of lithium disilicate ceramic were examined for precipitates after the etching and neutralizing process.
Materials And Methods: The HF permeability of the following isolation agents (n=8) was investigated by positioning them over pH indicator paper under airtight conditions and applying 9% HF: latex rubber dam; elastic plastomer rubber dam; nitrile gloves; latex gloves; liquid rubber dam; Teflon; AZ strip.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!