Long Wavelength Near InfraRed (LW-NIR) spectrometer has wide applications. Miniaturization and low-cost are two major goals of the development of LW-NIR spectrometer in the industrial or research community. Under the background that having a trend of spectrometer miniaturization and integration, method and main problems involved in miniaturization of LW-NIR spectrometer through MEMS scanning mirror, such as the design strategy of the light-splitting optical system, selection considerations of the MEMS scanning mirror, design method of the preamplifier circuit, etc, have been presented in detail. A prototype of miniaturized LW-NIR spectrometer, with the spectrum range of detection of 900-2,055 nm, is designed and implemented using MEMS scanning mirror, InGaAs single detector unit with high sensitivity. Littrow optical layout is used for its light-splitting optical system, and the spectral resolution is between 9.4-16 nm at 1,000-1,965 nm detection wavelength range. The prototype is successfully applied in LW-NIR spectrum measurement on pure water and ethanol aqueous solution, and a forecast analysis on ethanol aqueous solution concentration is also demonstrated. Through adopting MEMS scanning mirror into the spectrometer system, the complexity of the mechanical scanning fixtures and its controlling mechanism is greatly reduced therefore the size of the spectrometer is reduced. Furthermore, due to MEMS scanning mirror technology, LW-NIR spectrometer with single InGaAs detector is achieved, thus the cost reduction of the NIR spectrometer system is also realized because the expensive InGaAs arrays are avoided.

Download full-text PDF

Source

Publication Analysis

Top Keywords

mems scanning
24
lw-nir spectrometer
20
scanning mirror
20
spectrometer
10
long wavelength
8
wavelength infrared
8
mirror design
8
light-splitting optical
8
optical system
8
ethanol aqueous
8

Similar Publications

Atomic Fabrication of 2D Materials Using Electron Beams Inside an Electron Microscope.

Nanomaterials (Basel)

October 2024

SEU-FEI Nano-Pico Center, Key Laboratory of MEMS of Ministry of Education, Southeast University, Nanjing 210096, China.

Two-dimensional (2D) materials have garnered increasing attention due to their unusual properties and significant potential applications in electronic devices. However, the performance of these devices is closely related to the atomic structure of the material, which can be influenced through manipulation and fabrication at the atomic scale. Transmission electron microscopes (TEMs) and scanning TEMs (STEMs) provide an attractive platform for investigating atomic fabrication due to their ability to trigger and monitor structural evolution at the atomic scale using electron beams.

View Article and Find Full Text PDF

Fabrication of surface functionalized QCM sensor for BTX detection at ambient conditions.

Talanta

February 2025

Department of Instrumentation & Electronics Engg., Jadavpur University, Salt Lake Campus Block LB, Kolkata 700106, India. Electronic address:

Article Synopsis
  • - The study focuses on creating efficient gas sensors using Quartz Crystal Microbalance (QCM) coated with Tungsten Oxide (WO) to detect harmful BTX compounds (Benzene, Toluene, and Xylene) in the environment.
  • - Various scientific methods such as Optical Profilometry, Scanning Electron Microscopy, and X-ray Diffraction were used to analyze the sensor's surface and structure, revealing an optimal film thickness of about 200.81 nm with a granular microstructure.
  • - The developed sensor demonstrated high sensitivity, with the best response to xylene (5.10 Hz/ppm), quick response times, and impressive repeatability (99%) and reproducibility (98%), making it a promising
View Article and Find Full Text PDF

Micromirrors have recently emerged as an essential component in optical scanning technology, attracting considerable attention from researchers. Their compact size and versatile capabilities, such as light steering, modulation, and switching, are leading them as potential alternatives to traditional bulky galvanometer scanners. The actuation of these mirrors is critical in determining their performance, as it contributes to factors such as response time, scanning angle, and power consumption.

View Article and Find Full Text PDF

Background: The use of mobilizing agents for hematopoietic stem cell (HSC) transplantation is insufficient for an increasing number of patients. We previously reported lipid made endocannabinoid (eCB) ligands act on the human bone marrow (hBM) HSC migration in vitro, lacking long term stability to be therapeutic candidate. In this study, we hypothesized if a novel 2-AG-loaded polycaprolactone (PCL)-based nanoparticle delivery system that actively targets BM via phosphatidylserine (Ps) can be generated and validated.

View Article and Find Full Text PDF

High-efficiency and thermally stable FACsPbI perovskite photovoltaics.

Nature

November 2024

State Key Laboratory of Advanced Chemical Power Sources, Frontiers Science Center for New Organic Matter, Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), College of Chemistry, Nankai University, Tianjin, P. R. China.

α-FACsPbI is a promising absorbent material for efficient and stable perovskite solar cells (PSCs). However, the most efficient α-FACsPbI PSCs require the inclusion of the additive methylammonium chloride, which generates volatile organic residues (methylammonium) that limit device stability at elevated temperatures. Previously, the highest certified power-conversion efficiency of α-FACsPbI PSCs without methylammonium chloride was only approximately 24% (refs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!