The purpose of this study was to demonstrate clinical outcomes of sandblasted, large-grit, acid-etched (SLA)-surfaced tapered implants when early loaded in partially edentulous spaces in the maxilla. SLA-surfaced implants were placed in participants in the maxillary posterior edentulous area. At the time of definitive restoration, participants were allocated either to group 1 (3-month loading group) or group 2 (6-month loading group). A total of 36 participants (18 people [35 implants] in group 1 and 18 [33 implants] in group 2) were analyzed. Clinical outcomes, including survival rate and peri-implant parameters such as marginal bone loss were measured 1 year after loading. The survival rate was 97.0% in group 1 and 100% in group 2. Marginal bone loss was 0.22 ± 0.34 mm in group 1 and 0.17 ± 0.25 mm in group 2 at 1 year after loading (P = .488). There were no significant differences between groups in keratinized mucosal width (P = .206), Plaque Index (P = .677), or Gingival Index (P = .558). With adequate remaining bone height and primary implant stability achieved, the 3-month early loading of SLA-surface tapered implants may be a viable choice when restoring posterior maxillary edentulous areas.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/prd.1789 | DOI Listing |
Arch Orthop Trauma Surg
January 2025
Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
Total hip arthroplasty (THA) is a very successful operation. Once the problem of implant fixation was solved with the use of bone cement, the next development steps focused on improving the bearing. Weber, a Swiss surgeon, introduced the first modular heads in THA.
View Article and Find Full Text PDFNat Protoc
January 2025
Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, Italy.
Implantable multifunctional probes have transformed neuroscience research, offering access to multifaceted brain activity that was previously unattainable. Typically, simultaneous access to both optical and electrical signals requires separate probes, while their integration into a single device can result in the emergence of photogenerated electrical artifacts, affecting the quality of high-frequency neural recordings. Among the nontrivial strategies aimed at the realization of an implantable multifunctional interface, the integration of optical and electrical capabilities on a single, minimally invasive, tapered optical fiber probe has been recently demonstrated using fibertrodes.
View Article and Find Full Text PDFClin Implant Dent Relat Res
February 2025
Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, Minnesota, USA.
Objectives: This study evaluated different designs of the conical implant-abutment connection (IAC) and their resistance to microgap formation under oblique loads as specified by the ISO standard for testing dental implants. Also evaluated was the effect of deviations from the ISO specifications on the outcomes.
Methods: Finite element analysis was conducted to compare the microgap formation and stress distribution among three conical IAC designs (A, B, and C) in two loading configurations: one compliant with ISO 14801 and one with a modified load adaptor (non-ISO).
Clin Ophthalmol
January 2025
Harvard Eye Associates, Laguna Hills, CA, USA.
Purpose: To assess real-world efficacy and safety of standalone travoprost intracameral implant (iDose TR) implantation by a US glaucoma surgeon in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT).
Methods: This non-randomized, retrospective, unmasked, consecutive case series included all cases of standalone iDose TR implantation from a single US glaucoma surgeon since the product's approval by the US Food and Drug Administration (FDA) in December 2023. Patients were pseudophakic, had OAG or OHT, and had undergone prior SLT and/or bimatoprost intracameral implant injection (Durysta).
Cureus
January 2025
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.
Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.