A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vitro hydrodynamic, transient, and overtime performance of a miniaturized valve for hydrocephalus. | LitMetric

Reliable cerebrospinal fluid (CSF) draining methods are needed to treat hydrocephalus, a chronic debilitating brain disorder. Current shunt implant treatments are characterized by high failure rates that are to some extent attributed to their length and multiple components. The designed valve, made of hydrogel, steers away from such protracted schemes and intends to provide a direct substitute for faulty arachnoid granulations, the brain's natural CSF draining valves, and restore CSF draining operations within the cranium. The valve relies on innate hydrogel swelling phenomena to strengthen reverse flow sealing at idle and negative pressures thereby alleviating common valve failure mechanisms. In vitro measurements display operation in range of natural CSF draining (cracking pressure, PT ~ 1-110 mmH2O and outflow hydraulic resistance, Rh ~ 24-152 mmH2O/mL/min), with negligible reverse flow leakage (flow, QO > -10 µL/min). Hydrodynamic measurements and over-time tests under physically relevant conditions further demonstrate the valve's operationally-reproducible properties and strengthen its validity for use as a chronic implant.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-015-1291-xDOI Listing

Publication Analysis

Top Keywords

csf draining
16
natural csf
8
reverse flow
8
vitro hydrodynamic
4
hydrodynamic transient
4
transient overtime
4
overtime performance
4
performance miniaturized
4
valve
4
miniaturized valve
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!