Biomechanical study of dynamic changes in L4-L5 foramen surface area in flexion and extension after implantation of four interspinous process devices.

Orthop Traumatol Surg Res

Department of Orthopaedic Surgery, hôpital de la Pitié-Salpêtrière, AP-HP, UPMC University, 75013 Paris, France.

Published: April 2015

Background: Lumbar spinal stenosis is a major public health issue. Interspinous devices implanted using minimally invasive techniques may constitute an alternative to the reference standard of bony decompression with or without intervertebral fusion. However, their indications remain unclear, due to a paucity of clinical and biomechanical data. Our objective was to evaluate the effects of four interspinous process devices implanted at L4-L5 on the intervertebral foramen surface areas at the treated and adjacent levels, in flexion and in extension.

Materials And Method: Six fresh frozen human cadaver lumbar spines (L2-sacrum) were tested on a dedicated spinal loading frame, in flexion and extension, from 0 to 10 N·m, after preparation and marking of the L3-L4, L4-L5, and L5-S1 foramina. Stereoscopic 3D images were acquired at baseline then after implantation at L4-L5 of each of the four devices (Inspace(®), Synthes; X-Stop(®), Medtronic; Wallis(®), Zimmer; and Diam(®), Medtronic). The surface areas of the three foramina of interest were computed.

Results: All four devices significantly opened the L4-L5 foramen in extension. The effects in flexion separated the devices into two categories. With the two devices characterized by fixation in the spinous processes (Wallis(®) and Diam(®)), the L4-L5 foramen opened only in extension; whereas with the other two devices (X-Stop(®) and Inspace(®)), the L4-L5 foramen opened not only in extension, but also in flexion and in the neutral position. None of the devices implanted at L4-L5 modified the size of the L3-L4 foramen. X-Stop(®) and Diam(®) closed the L5-S1 foramen in extension, whereas the other two devices had no effect at this level.

Conclusion: Our results demonstrate that interspinous process devices modify the surface area of the interspinous foramina in vitro. Clinical studies are needed to clarify patient selection criteria for interspinous process device implantation.

Level Of Evidence: Level IV. Investigating an orthopaedic device.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2014.11.016DOI Listing

Publication Analysis

Top Keywords

l4-l5 foramen
16
interspinous process
16
process devices
12
devices implanted
12
devices
11
l4-l5
8
foramen surface
8
surface area
8
flexion extension
8
implanted l4-l5
8

Similar Publications

A case of lumbar spinal solitary fibrous tumor or hemangiopericytomas.

Surg Neurol Int

August 2024

Department of Neurosurgery, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, Jeddah, Saudi Arabia.

Article Synopsis
  • Solitary fibrous tumors (SFTs) make up a small percentage (3.7%) of soft-tissue sarcomas, with a low annual incidence rate, and primarily affect the central nervous system, notably the brain more than the spine.
  • A 46-year-old woman experienced sciatica for 18 months and was found to have a dumbbell-shaped tumor at the L4-L5 level causing nerve compression, diagnosed through an MRI.
  • She underwent a successful surgical procedure, a left hemi-laminectomy, and the tumor was confirmed post-surgery to be a WHO Grade I hemangiopericytoma, indicating a low-grade tumor.
View Article and Find Full Text PDF

Background: Lumbar-iliac fixation (LIF) is a common treatment for Tile C1.3 pelvic fractures, but different techniques, including L4-L5/L5 unilateral LIF (L4-L5/L5 ULIF), bilateral LIF (BLIF), and L4-L5/L5 triangular osteosynthesis (L4-L5/L5 TOS), still lack biomechanical evaluation. The sacral slope (SS) is key to the vertical shear of the sacrum but has not been investigated for its biomechanical role in lumbar-iliac fixation.

View Article and Find Full Text PDF

Objective: Uniportal full-endoscopic foraminotomy offers a promising alternative to conventional surgical methods for individuals afflicted by lumbar foraminal stenosis. This study aims to evaluate the efficacy and clinical outcomes of uniportal full-endoscopic foraminotomy in patients diagnosed with lumbar foraminal stenosis.

Methods: A comprehensive retrospective analysis was conducted on individuals who underwent full-endoscopic foraminotomy in our medical center, between January 2018 and December 2019.

View Article and Find Full Text PDF

A toddler was diagnosed with extraosseous Ewing's sarcoma, primary large epidural paraspinal soft tissue in the lumbar region encasing the cord and neural foramen from D12-L1 to L4-L5. After eight cycles of induction chemotherapy with vincristine, doxorubicin, and cyclophosphamide alternating with etoposide and ifosfamide, F-FDG positron emission tomography/computed tomography ( F-FDG-PET/CT) scan confirmed no active disease. Later external beam radiotherapy (EBRT) at D10-L5 was completed.

View Article and Find Full Text PDF

Transforaminal selective nerve root blocks are commonly performed for low back pain but are not without risk. This case report describes a 55-year-old man who underwent transforaminal selective nerve root block at the left lumbar (L) 4, L5, and sacral (S) 1 levels for radiating low back pain in the setting of moderate narrowing of the left L4-L5 foramen with impingement on the exiting left L4 nerve roots seen on magnetic resonance imaging (MRI). He developed left foot drop immediately after the procedure and presented to the acupuncture clinic two weeks later with persistent pain, left foot drop, and paresthesia of the left lateral shin.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!