Background: The addition of electroanatomic mapping to a standard echo-guided endomyocardial biopsy could identify areas of abnormal pathology and increase the diagnostic yield of the procedure.

Methods And Results: In this demonstration of a novel technique, a 45-year-old woman with clinical suspicion for cardiac sarcoidosis underwent right ventricular bipolar electroanatomical mapping with identification of areas of signal fractionation and low voltage. A bioptome, configured to record an electrogram from the tip, was then visualized on the three-dimensional electroanatomic mapping (3DEAM) system, and directed to these areas. The biopsy was assisted by the use of a steerable introducer sheath, and by recording unipolar and extended bipolar signals from the bioptome tip. A prominent change in the signal was detected by the electrode at the bioptome tip when the jaws closed on the endomyocardial tissue. Patient tolerated the procedure without complications, and the biopsied samples were appropriate for pathological analysis.

Conclusions: Using existing technology, the 3DEAM, which integrates unipolar and bipolar signal from the bioptome tip, is feasible, and can be safely added to a standard echocardiographically guided endomyocardial biopsy. Future studies should investigate whether such a technique could increase the safety and diagnostic yield of endomyocardial biopsies in patients with suspected cardiomyopathies.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1753944715574660DOI Listing

Publication Analysis

Top Keywords

electrode bioptome
8
electroanatomic mapping
8
endomyocardial biopsy
8
diagnostic yield
8
endomyocardial
5
bioptome
5
endomyocardial biopsy-integrating
4
biopsy-integrating electrode
4
bioptome background
4
background addition
4

Similar Publications

Successful extraction of right ventricular lead remnants using the FlexCath® steerable sheath.

J Interv Card Electrophysiol

January 2016

Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, Johns Hopkins Hospital, The Johns Hopkins University School of Medicine, 1800 Orleans Street, Sheikh Zayed Tower, 7125Q, Baltimore, MD, 21287, USA.

In patients undergoing laser lead extraction, incomplete or failed lead removal occur in over 3 % of leads. Because the current available tools have limitations in reaching the right ventricle (RV), the procedure becomes challenging when the lead breaks and its fragments remain lodged in the RV. We describe two cases in which the FlexCath® steerable sheath, normally used in cryoballoon catheter ablation for atrial fibrillation, was useful in directing a bioptome to right ventricular lead fragments and thus allowing for complete lead extraction.

View Article and Find Full Text PDF

Introduction: Right ventricular perforation during endomyocardial biopsy is an unusual, although potentially life-threatening, complication caused with the tip of the bioptome. The majority of perforations in heart transplant patients can be managed without surgery owing to adhesions nearly obliterating pericardial space.

Case Report: We report a case of heart transplant patient who suffered right ventricular perforation as a consequence of incidental extraction of a temporary epicardial pacemaker wire during a routine endomyocardial biopsy sampling.

View Article and Find Full Text PDF

Background: The addition of electroanatomic mapping to a standard echo-guided endomyocardial biopsy could identify areas of abnormal pathology and increase the diagnostic yield of the procedure.

Methods And Results: In this demonstration of a novel technique, a 45-year-old woman with clinical suspicion for cardiac sarcoidosis underwent right ventricular bipolar electroanatomical mapping with identification of areas of signal fractionation and low voltage. A bioptome, configured to record an electrogram from the tip, was then visualized on the three-dimensional electroanatomic mapping (3DEAM) system, and directed to these areas.

View Article and Find Full Text PDF

A previous report described our preliminary experience with a highly successful pacing lead removal system (VasoExtor). Extending this experience, we found it necessary to use additional tools to enhance the success of percutaneous lead extraction with this system. In the present series, we used the standard locking stylets (S and K), and recently, one newer type of stylet (Magic) over the last 3 years in 34 patients to extract 48 pacemaker leads in 31 patients and 3 defibrillator (ICD) leads in 3 patients.

View Article and Find Full Text PDF

The Telectronics Accufix Atrial "J" pacing lead poses a mechanical risk to patients of retention wire fracture and protrusion. Standard lead extraction techniques include percutaneous approaches, which are associated with significant risk of morbidity and mortality, and open procedures, which necessitate thoracotomy. In nine patients referred with Class III retention wire fractures, attempts were made to snare the protruding retention wire from a femoral approach using snare devices and bioptomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!