Effects of Nei-Guan (P6) Acupressure Wristband: On Nausea, Vomiting, and Retching in Women After Thyroidectomy.

Cancer Nurs

Author Affiliations: College of Nursing, Keimyung University, Daegu, Korea (Ms Kwon and Dr Shin); and Department of Medical Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania (Dr Juon).

Published: June 2017

Background: Postoperative nausea and vomiting (PONV) after thyroidectomy is a common health problem in the recovery room.

Objective: The aim of this study is to examine the effect of the Nei-Guan (P6) acupressure wristband for PONV among patients undergoing thyroidectomy.

Methods: Sixty Korean female participants were assigned to 1 of 3 groups (n = 20 each). The control group received usual care without the wristband. The placebo group received usual nursing care plus a wristband at the non-P6 site. The treatment group received usual care plus a wristband at the P6 acupoint 30 minutes before anesthesia; the wristband was removed before leaving the recovery room. Data were collected at 3 periods: in the recovery room and at 6 and 24 hours after surgery.

Results: The nausea scores of the treatment group were significantly lower than the scores of the placebo or control groups in the recovery room (F = 6.229, P = .044). There were no significant differences in vomiting or retching among the groups.

Conclusions: The P6 stimulation with wristband suppressed nausea right after thyroidectomy in the recovery room but did not suppress subsequent vomiting or retching.

Implication For Practice: The findings indicate that P6 acupressure has the short-term effect of relieving nausea but not vomiting and retching. Use of P6 wristband holds promise and suggests the need for further testing in a larger randomized clinical trial. Identifying other acupoints is recommended to achieve successful management of PONV.

Download full-text PDF

Source
http://dx.doi.org/10.1097/NCC.0000000000000243DOI Listing

Publication Analysis

Top Keywords

recovery room
16
nausea vomiting
12
vomiting retching
12
group received
12
received usual
12
care wristband
12
nei-guan acupressure
8
wristband
8
acupressure wristband
8
usual care
8

Similar Publications

Background: Petersen's hernia occurring through the epiploic foramen of the greater omentum, is an uncommon type of internal hernia. When it presents with complications such as chylous ascites, which is the lymphatic fluid accumulation in the abdominal cavity, it is particularly rare. Following laparoscopic total gastrectomy and Roux-en-Y anastomosis, the incidence of this condition is exceedingly low.

View Article and Find Full Text PDF

Identification of microorganisms at different times in a bioleaching process for the recovery of gold and silver from minerals in oxide form.

Heliyon

January 2025

Department of Chemical and Biochemical Engineering, National Technological Institute of Mexico (TecNM), Durango Institute of Technology (ITD), Felipe Pescador 1830 Ote. Col, Nueva Vizcaya, Durango, Dgo, 34080, Mexico.

In this study, gold and silver were recovered through a bioleaching process conducted at room temperature over 11 days. Native bacteria and varying ratios of mineral pulp to culture medium (20/80, 37.5/62.

View Article and Find Full Text PDF

Sensitive H sensors play key roles in the large-scale and safe applications of H. In this study, we developed novel ternary Pd-loaded SnO@WO core-shell structures by hydrothermal and reduction methods. The compositions of the optimized ternary core-shell structures (Pd-SW-2) are prepared on the basis of the optimal binary core-shell structures (SW-X) according to the sensing performances to H.

View Article and Find Full Text PDF

Objective: Enhancing ventilatory effort during pulmonary function testing can help reveal flow limitations not evident in normal tidal breathing. This study aimed to assess the efficacy and tolerability of using a CO2/O2 gas mixture to enhance tidal breathing with a barometric whole-body plethysmography system in both healthy cats and those with feline lower airway disease (FLAD).

Methods: This prospective study included healthy cats and those with FLAD, which underwent pulmonary function testing and were exposed to a 10% CO2/90% O2 gas mixture in a barometric whole-body plethysmography chamber, with CO2 concentrations maintained within the target range of 5% to 10%.

View Article and Find Full Text PDF

Sensing of hazardous gases has an important role in ensuring safety in a variety of industries as well as environments. Mainly produced by the combustion of fossil fuels and other organic matter, ethanol is a dangerous gas that endangers human health and the environment. Stability and sensing sensitivity are major considerations when designing gas sensors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!