A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and efficacy of a novel silver-impregnated urinary catheter system for preventing catheter-associated bacteriuria: a pilot randomized clinical trial. | LitMetric

Background: The purpose of this study was to evaluate the safety of a novel silver-impregnated Foley catheter system designed to prevent catheter-associated bacteriuria and funguria, assess recruitment feasibility for a future pivotal trial, and preliminarily assess efficacy.

Methods: This single-center, randomized controlled trial at a university hospital involved adult neurosurgical patients expected to have a urinary catheter for ≥24 hours. Subjects were randomized to a novel silver-impregnated (test) Foley catheter system or a control system. They were followed for 30 days (or until discharge) while catheterized and for up to 48 hours after catheter removal, with daily bacteriuria testing and assessment for symptoms of infection and catheter intolerance.

Results: Ninety-five subjects were randomized (intention-to-treat [ITT] population). Of these, 61 subjects (64%) had a catheter for ≥24 hours without perioperative antibiotics beyond 24 hours (evaluable population). In the ITT population, 11 of 95 (12%) subjects had an asymptomatic bacteriuria (ABU) event. Compared with controls, test system recipients had a trend toward longer time to ABU in the ITT population (P = .08, log-rank test) and a longer time to ABU in the evaluable population (P = .03). All 6 ABU events caused by gram-negative bacilli occurred in the control group.

Conclusion: In this pilot randomized trial the test system was well tolerated and seemingly effective in preventing catheter-associated bacteriuria, especially with gram-negative bacilli. A pivotal study is warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5540320PMC
http://dx.doi.org/10.1016/j.ajic.2014.11.021DOI Listing

Publication Analysis

Top Keywords

novel silver-impregnated
12
catheter system
12
catheter-associated bacteriuria
12
urinary catheter
8
preventing catheter-associated
8
pilot randomized
8
foley catheter
8
catheter ≥24
8
≥24 hours
8
subjects randomized
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!