Anyplex™II HPV28 is a new PCR assay designed for HPV genotyping. It can detect 28 HPV types including 19 high-risk and 9 low-risk types. This study evaluated the performance of Anyplex™II HPV28 on 123 fresh cervical samples screened in parallel with HPV Sign® Genotyping Test. Of the 123 samples screened, 93 were positive, 15 negative, and 15 discordant. The total number of HPV positive samples combined was 108: 38 single infections and 70 multiple infections. The agreement between the two tests was 87.8%, κ=0.592. Genotype specific agreement was strong for HPV 16 (k=0.761), HPV 18 (k=0.674), and HPV 35 (k=0.796). Sensitivity and specificity of Anyplex™II HPV28 assay using HPV Sign® Genotyping Test as reference was 84.8% and 94%; conversely, sensitivity and specificity of HPV Sign® Genotyping Test was 29% and 99.5%. Anyplex™II HPV28 assay is a sensitive and specific assay suitable for HPV genotyping but requires clinical validation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jviromet.2015.02.018 | DOI Listing |
J Clin Microbiol
December 2024
International Agency for Research on Cancer, Lyon, France.
Despite first-void urine (FVU) being increasingly recognized as a credible specimen for human papillomavirus (HPV) detection, there is a lack of well-validated testing methods providing full quantitative genotyping required for vaccine impact monitoring from FVU samples. The Allplex HPV28 assay, capable of individually detecting 28 HPV genotypes, presents a promising method. We aimed to evaluate its genotype-specific performance on FVU samples, following optimization of FVU preanalytics.
View Article and Find Full Text PDFJ Virol Methods
December 2024
Scottish HPV Reference Laboratory, NHS Lothian, Royal Infirmary of Edinburgh, Little France, Edinburgh EH16 4SA, United Kingdom; HPV Research Group, University of Edinburgh, Edinburgh EH16 4TJ, United Kingdom.
Background: Self-sampling is now a key component within HPV-based cervical screening programmes to engage individuals and enhance participation. As self-sampling is relatively new, information on the influence of pre-analytical parameters such as transit-temperature and time between sampling and testing on HPV test results requires detailed investigation.
Methods: FLOQSwabs® and Evalyn Brushes® were used to assess HPV and cellular stability over a 30-week period (0w,4w,12w,30w) at 4 °C, ambient, and 37 °C.
Viruses
November 2024
Department of Obstetrics and Gynaecology, Faculty of Health Sciences, Walter Sisulu University, Mthatha 5100, South Africa.
J Natl Cancer Inst Monogr
November 2024
International Vaccine Institute, Seoul, Republic of Korea.
Vaccine
December 2024
Wits RHI, University of the Witwatersrand, Johannesburg, Gauteng, South Africa. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!