AI Article Synopsis

Article Abstract

Introduction: In recent years, new angle-stable plate implants with polyaxial screw direction were developed with the aim of an improved treatment of displaced 3- and 4-part fractures of the proximal humerus. There are only a few studies available about polyaxial implants in the treatment of 3- and 4-part proximal humerus fractures. Therefore, the aim of this study was to evaluate clinical results and complications of open reduction and internal fixation of displaced 3- and 4-part fractures using a polyaxial plate.

Patients And Methods: Within 51 months, 105 patients with a displaced 3- or 4-part fracture of the proximal humerus were treated with a polyaxial locking plate. The complications were evaluated and the Constant & Murley score was assessed and correlated with patient satisfaction ("very satisfied" to "not satisfied"). Additionally, the results were compared with those of monoaxial plates from the literature. Furthermore, the operative experience of the surgeons at the time of surgery was correlated with the objective results of the patients.

Results: 65 patients (average age: 71.3 ± 11.4 years; average follow-up: 19,6 ± 9,8 month [10-44 month]) with a displaced 3- or 4-part fracture were re-examined retrospectively (female: n = 54; male: n = 11). Overall, there were 27 3-part fractures and 38 4-part fractures. The Constant and Murley Score was on average 62.1 ± 16.5 points and the complication rate was 26 %. The most frequent complication was screw perforation through the humeral head. Patient satisfaction with clinical outcome was high within the whole study group. 40 % of the patients were "very satisfied" with their shoulder function, 29 % were "satisfied" ("fair": 12 %, "not satisfied": 19 %). Additionally, the operative experience of the surgeons influenced the final clinical result.

Conclusion: In comparison to the literature we could not delineate better clinical outcomes or lower complication rates with polyaxial implants compared to monoaxial plates in 3- and 4-part fractures. Nevertheless, the majority of patients were satisfied with the clinical result in the context of age-related shoulder function. In addition, a close correlation could be detected between the degree of satisfaction and the objectively measured shoulder function. A high level of operative experience is required to avoid typical complications and to achieve a good clinical result.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0034-1383354DOI Listing

Publication Analysis

Top Keywords

4-part fractures
20
displaced 4-part
16
proximal humerus
12
operative experience
12
shoulder function
12
4-part
8
treatment 4-part
8
humeral head
8
polyaxial implants
8
4-part fracture
8

Similar Publications

Objectives: To evaluate the clinical significance of stress shielding in patients who have undergone an uncemented reverse shoulder arthroplasty (RSA) with a proximally coated stem for complex proximal humeral fractures (PHF) comprising 3 or 4 parts, assessed at 2 years postoperatively. Additionally, this study aims to examine the correlation between tuberosity healing and clinical outcomes.

Methods: Single Centre.

View Article and Find Full Text PDF

Background: The optimal treatment of 3- and 4-part proximal humeral fractures in older adults remains controversial. This aim of this study was compare patient reported outcomes following reverse shoulder arthroplasty (RSA) or non-operative management in patients over 60 years old.

Methods: A retrospective review was undertaken of patients following 3- or 4-part proximal humeral fractures treated with RSA or non-operative treatment with minimum 2-year follow-up.

View Article and Find Full Text PDF

There is no consensus in the literature regarding the optimal treatment for complex proximal humerus fractures (PHFs). The aim of this study is to evaluate the clinical, functional, and radiological outcomes, and complications, associated with the Bilboquet implant in the treatment of PHFs. The search was conducted from the first description of the Bilboquet device in 1994 to June 2024, across PubMed, Web of Science, and Google Scholar, using specific keywords such as ("Bilboquet" OR "Bilboquet prosthesis" OR "Bilboquet device") AND ("proximal humerus fracture" OR "shoulder fracture"), along with Boolean operators.

View Article and Find Full Text PDF

Background: It is still unclear whether reverse total shoulder arthroplasty (RTSA) has advantages over traditional hemiarthroplasty (HA) and anatomic total shoulder arthroplasty (ATSA) in the treatment of complex shoulder joint diseases. Therefore, this study aims to evaluate the clinical effectiveness of RTSA in the treatment of complex shoulder joint diseases and further determine whether it is necessary to expand the indications of RTSA.

Method: We conducted a systematic search of studies published between January 1, 2012 and May 31, 2023 in PubMed, Embase, and Cochrane databases.

View Article and Find Full Text PDF

Background: Conventional techniques for the fixation of displaced proximal humeral fractures include the use of locking plates, intramedullary nailing, hemiarthroplasty and reverse shoulder replacement. Valgus-impacted fractures are a common subtype of proximal humeral fracture, but there are few publications concerning the outcomes of treatment. This study aims to review outcomes following an 'all-suture' technique for this fracture subtype without the use of transosseous sutures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!