Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The use of drug-eluting stents (DES) in patients at high risk of bleeding or thrombosis has not been prospectively studied; limited data are available in patients who have a low restenosis risk.
Objectives: This study sought to compare a hydrophilic polymer-based, second-generation zotarolimus-eluting stent (ZES) with a unique drug fast-release profile versus bare-metal stents (BMS) under similar durations of dual-antiplatelet therapy (DAPT).
Methods: We randomly assigned 1,606 patients with stable or unstable symptoms, and who on the basis of thrombotic bleeding or restenosis risk criteria, qualified as uncertain candidates for DES, to receive ZES or BMS. DAPT duration was on the basis of patient characteristics, rather than stent characteristics, and allowed for a personalized 1-month dual antiplatelet regimen. The primary endpoint was the risk of 1-year major adverse cardiovascular events (MACE), which included death, myocardial infarction (MI), or target vessel revascularization (TVR).
Results: Median DAPT duration was 32 days (interquartile range [IQR]: 30 to 180 days) and did not differ between the groups. In the ZES group, 140 patients (17.5%) reached the primary endpoint, compared with 178 patients (22.1%) in the BMS group (hazard ratio: 0.76; 95% confidence interval: 0.61 to 0.95; p = 0.011) as a result of lower MI (2.9% vs. 8.1%; p < 0.001) and TVR rates (5.9% vs.10.7%; p = 0.001) in the ZES group. Definite or probable stent thrombosis was also significantly reduced in ZES recipients (2.0% vs. 4.1%; p = 0.019).
Conclusions: Compared with BMS, DES implantation using a stent with a biocompatible polymer and fast drug-eluting characteristics, combined with an abbreviated, tailored DAPT regimen, resulted in a lower risk of 1-year MACE in uncertain candidates for DES implantation. (Zotarolimus-eluting Endeavor Sprint Stent in Uncertain DES Candidates [ZEUS] Study; NCT01385319).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacc.2014.11.053 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!