One-year follow-up of conduction disturbances following transcatheter aortic valve implantation.

J Cardiovasc Med (Hagerstown)

aUniversity of Torino - Department of Surgical Sciences, Division of Cardiac Surgery bUniversity of Torino - Department of Medical Sciences, Division of Cardiology c'Città della Salute e della Scienza' Hospital, Division of Cardiology, Torino, Italy.

Published: April 2015

Aims: To describe the postprocedural and 1-year follow-up incidence of heart conduction disturbances in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).

Methods: Ninety-five patients were enrolled from 2008 to 2011 (mean age 81.8 ± 7.2 years, 63.1% women). Clinical and ECG data were recorded at admission, discharge, and 3, 6 and 12 months following TAVI.

Results: Fifty-seven Edwards SAPIEN (31 transapical, 26 transfemoral) and 38 transfemoral CoreValve implants were used. Two (2.1%) patients died during the procedure and 11 (11.6%) patients received a pacemaker prior to discharge (7 CoreValve, 3 transapical, 1 transfemoral SAPIEN; P = 0.18). Among the surviving patients not receiving a pacemaker, TAVI increased the PQ interval (176 ± 29 vs. 188 ± 36 ms; P = 0.001), QRS width (90 ± 15 vs. 108 ± 26 ms; P < 0.001), and first-grade atrioventricular block (17 vs. 29%; P < 0.001). Postprocedural complete left bundle branch block was reported most in transapical (from 10 to 36%; P = 0.01) and CoreValve (from 8 to 64%; P < 0.001) recipients compared to the transfemoral SAPIEN group. At the 12-month follow-up, 24 (25.3%) patients had died [two (2.1%) sudden deaths] and four (4.2%) required pacemaker implantation. Among the survivors not receiving a pacemaker at the 1-year follow-up, the PQ interval (178 ± 27 vs. 188 ± 36 ms; P = 0.39) remained unchanged in the ECG, whereas the QRS width (100 ± 22 vs. 108 ± 26 ms; P = 0.008) decreased compared to measurements taken at discharge.

Conclusion: Conduction disturbances following TAVI primarily develop during hospitalization and subsequently stabilize. However, the small percentage of patients suffering sudden death or pacemaker implantation requires attention.

Download full-text PDF

Source
http://dx.doi.org/10.2459/JCM.0000000000000179DOI Listing

Publication Analysis

Top Keywords

conduction disturbances
8
transcatheter aortic
8
aortic valve
8
valve implantation
8
transapical transfemoral
8
patients
5
one-year follow-up
4
follow-up conduction
4
disturbances transcatheter
4
implantation aims
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!